ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 – User and Installation Manual
23
5.5.6 12V constant voltage
Outputs 1 and 2 are configured as full outputs. Smart
terminal is current limited and set to 12V constant voltage.
5.5.7 24V constant voltage (24V model only)
Outputs 1 and 2 are configured as full outputs, Smart
terminal is current limited and set to 24V constant voltage.
5.5.8 12V 3-step+ (24V model only)
Outputs 1 and 2 are configured as full outputs. Smart
terminal is current limited and set to 3-step+ charge
process. In 12V 3-step+ configuration the following battery
types can be selected: AGM, GEL, flooded, AGM Spiral.
The maximum current is set to 10A by default but can be
changed in the configuration [5-10A].
5.6 Maintenance
No specific maintenance to the ChargeMaster Plus is
required. Examine your electrical installation on a regular
basis, at least once a year. Defects such as loose
connections, burnt wiring etc. must be corrected
immediately.
If necessary, use a soft clean cloth to clean enclosure of
the ChargeMaster Plus. Do not use any liquids or
corrosive substances, such as solvents, alcohol, petrol or
abrasive components.
5.7 Failures
The ChargeMaster Plus is protected against overload,
short circuit, overheating and under and over voltage. If a
fault condition occurs, the MODE button turns red and the
Battery 1, 2 & 3 LED indicate an error code. See section
CAUTION!
The ChargeMaster Plus is not protected
against serious over voltage (>275VAC) on the
AC input.
Note:
As long as there is no error code shown, no failure
is detected: the ChargeMaster Plus is operating
normally!
5.8 History
Connect the ChargeMaster Plus to MasterBus in order to
be able to see the history data stored in the ChargeMaster
Plus.