16
ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 – User and Installation Manual
4.2.7 History
This menu shows the absolute maximum readings.
Value
Meaning
Value range
Charger
Days running
Total run time in charger mode
(read only)
Output 1
Highest voltage
Highest detected DC voltage output 1
(read only)
Lowest voltage
Lowest detected DC voltage output 1
(read only)
Total Ah’s
Total charged Ah’s
(read only)
Output 2
Highest voltage
Highest detected DC voltage output 2
(read only)
Lowest voltage
Lowest detected DC voltage output 2
(read only)
Total Ah’s
Total charged Ah’s
(read only)
Smart terminal
Highest voltage
Highest detected DC voltage Smart terminal
(read only)
Lowest voltage
Lowest detected DC voltage Smart terminal
(read only)
Total Ah’s
Total charged Ah’s
(read only)
Total Ah’s in
Total charged Ah’s using the smart terminal as input
(read only)
4.2.8 Configuration
Below parameters can be changed via the MasterBus network by means of a remote control panel or by means of an interface
connected to a PC with MasterAdjust software. See applicable user manuals for details.
Value
Meaning
Factory setting
Value range
Device
Language
Menu language of this device
English
EN, NL, DE, FR, ES, IT, NO, SV, FI, DA
Name
Name of this device. This name will be
recognized by all devices connected to the
MasterBus
CHG
ChargeMaster
0-12 chars
MB
communication
Select if MasterBus communication is
available when only DC power is available.
Smart on
Smart on, Always on
Charger
Method
Charge method
3-Step+
3-Step+, constant voltage
Maximum
current
Maximum DC output current
Depending on
model, 100%
Depending on model 20-100%
Battery type
Type of battery
Flooded
User defined, AGM, GEL, Flooded, AGM
Spiral, Flooded traction, Flooded calcium,
MLI
Temp.
compensate
Temperature depended charge voltage
compensation
-0,030V/°C/
-0,060V/°C
-1,000/+1,000V/°C
Smart terminal Smart terminal operation mode
10A Starter
Starter, alternator, Follow main,
Follow main+alternator, 12V constant
voltage, 24V constant voltage*, 12V 3-
step+*
Maximum
current
Smart terminal maximum DC output current 40/20A
5-40/20A
Input threshold Voltage threshold used to switch over when
Smart Terminal acts as VSR
13,75/27.50V
8-16/16-32V
Input current
Smart terminal maximum DC input current
40/20A
5-40/20A
Bulk
Voltage
Bulk voltage (@ 25
°
C); see section 5.4
14.40/28.80V
0-15.50/0-31.00V
Minimum time
Minimum time of the Bulk phase since
Start
bulk timer
120sec
0-240sec
Start time at
Battery voltage trigger point to start the bulk
timer
13.25/26.50V
(read only)