background image

WARRANTY

Use only Microbore Autoanalysis tubing with 
MASTERFLEX C/L pumps to ensure optimum

performance. Use of other tubing may void 

applicable warranties.

The Manufacturer warrants this product to be free from 
significant deviations from published specifications. If repair
or adjustment is necessary within the warranty period, the
problem will be corrected at no charge if it is not due to 
misuse or abuse on your part, as determined by the
Manufacturer. Repair costs outside the warranty period, or
those resulting from product misuse or abuse, may be
invoiced to you.

The warranty period for this product is one (1) year from
date of purchase. 

PRODUCT RETURN

To limit charges and delays, contact the seller or Manufacturer
for authorization and shipping instructions before returning the
product, either within or outside of the warranty period. When
returning the product, please state the reason for the return.
For your protection, pack the product carefully and insure it
against possible damage or loss. 
Any damages resulting from improper packaging are your
responsibility.

TECHNICAL 
ASSISTANCE

If you have any questions about the use of this product, 
contact the Manufacturer or authorized seller.

9

®

Summary of Contents for C/L 77122-04

Page 1: ...or use with a series of tubing sizes that provide flow rates in the range of 2 0 L min to 50 mL min 77122 04 77122 14 77122 24 77122 06 77122 16 77122 26 Model No A 1299 1073B Edition 03 US Canada onl...

Page 2: ...tal use and accordingly have not been submitted for FDA approval TABLE OF CONTENTS Title Page SAFETY PRECAUTIONS 2 INTRODUCTION 3 GENERAL DESCRIPTION 4 SETUP 5 Selecting Tubing Size 5 Installing Tubin...

Page 3: ...System is designed to pump fluid through Microbore tubing by means of peristaltic action at very low flow rates It is ideal for sanitizers reagent dispensing analyzers printing systems controlled fee...

Page 4: ...Rotor contains four rollers for minimum pulsation All units operate from an External DC Power Supply The AC models are supplied with a Universal Power Supply which provides a DC output for connection...

Page 5: ...Tubing Retainers Figure 4 3 Once the tubing is in place close the Door and the Occlusion Bed will automatically align itself within the pump Figure 5 4 Insert the tubing into one of the Tubing Retaine...

Page 6: ...wer Supply unit Connect the External Power Supply to the applicable input voltage source and the output of the External Power Supply to the DC input connector on the pump unit Refer to Specifications...

Page 7: ...Tube life is decreased with increased operating speed Priming Pump System The MAX Push Button is used for priming and purging the Pump System When MAX is depressed the pump operates at maximum speed...

Page 8: ...Level Remote Start Stop Contact Closure connection at terminal strip contacts 3 and 4 Construction Dimensions L x W x H 7 0 in x 3 5 in x 3 5 in 17 8 cm x 8 9 cm x 8 9 cm Weight 1 5 pounds 0 68 kg Co...

Page 9: ...r those resulting from product misuse or abuse may be invoiced to you The warranty period for this product is one 1 year from date of purchase PRODUCT RETURN To limit charges and delays contact the se...

Page 10: ...g Use of tubing other than that specified will result in poor pumping performance and or pump system damage and voiding of applicable warranty Available Microbore Autoanalysis Tubing NOTE White indica...

Page 11: ...385 3100 13000 32 0 051 1 30 485 3850 16300 34 0 056 1 42 565 4500 19100 36 0 060 1 52 635 5100 21300 38 0 065 1 65 730 5850 24700 40 0 073 1 85 885 7100 29800 42 0 081 2 06 1050 8500 35200 44 0 090...

Page 12: ...Toll Free 1 800 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 EN809 manufactured by Cole Parmer Instrument Company 28W092 Commercial Avenue Barrington IL 60010 techinfo ma...

Reviews: