Output:

Operating Speed:

Models 77122-04

1.7 to 10 rpm

and 77122-06

Models 77122-14

13 to 80 rpm

and 77122-16

Models 77122-24

50 to 300 rpm

and 77122-26

Maximum No. of Tubes:

1

Direction of rotation:

Clockwise and 
Counterclockwise

Input:

Supply Voltage/Frequency:

Model 77122-04, -14, -24

115V AC nominal, 50/60 Hz
(90–130V AC) @ 400 mA AC
230V AC nominal, 50/60 Hz
(190–260V AC) @ 250 mA max.

Model 77122-06, -16, -26

12.0V DC nominal, 
(11.0–15.0V DC) @ 2.4 A DC

Power Input:

11.0–15.0V DC to terminals
1 and 2 of terminal strip or 
External Power Supply

Installation Category:

77122-04, -14, -24

Category II per IEC664 
(Local level—appliances,
portable equipment, etc.)

77122-06, -16, -26

Category I per IEC664
(Signal Level)

Remote Start/Stop:

Contact Closure connection
at terminal strip contacts 3
and 4

Construction:

Dimensions (L x W x H):

7.0 in x 3.5 in x 3.5 in
(17.8 cm x 8.9 cm x 8.9 cm)

Weight:

1.5 pounds (0.68 kg)

Color:

Black

Material:

Pump Head:

PPS, polyester 
and stainless steel

Case:

NORYL

®

Enclosure Rating:

IP22 per IEC529

Environment:

Operating Temperature:

32°F to 105°F (0°C to 40°C)

Maximum Operating 
Pressure: 15 

PSIG

Noise Level: 

<70dBa @ 1 meter

Storage Temperature:

–49°F to 149°F (–45°C to 65°C)

Humidity (Non-cond):

10% to 90%

Altitude:

Less than 6600 ft (2000 m)

Pollution Degree:

Pollution Degree 2 per IEC664
(Indoor usage — lab, office)

Compliance (For CE Mark):

EN61326-1/A2: 2001 (EMC Directive)
EN809 (EU Machinery Directive)
2011/65/EU (RoHS Directive)
Converter is UL, cUL listed and CE, CCC approved.
Regulatory agency specifications not applicable to the 
balance of the unit due to low voltage.

SPECIFICATIONS

Summary of Contents for C/L 77122-04

Page 1: ...or use with a series of tubing sizes that provide flow rates in the range of 2 0 L min to 50 mL min 77122 04 77122 14 77122 24 77122 06 77122 16 77122 26 Model No A 1299 1073B Edition 03 US Canada onl...

Page 2: ...tal use and accordingly have not been submitted for FDA approval TABLE OF CONTENTS Title Page SAFETY PRECAUTIONS 2 INTRODUCTION 3 GENERAL DESCRIPTION 4 SETUP 5 Selecting Tubing Size 5 Installing Tubin...

Page 3: ...System is designed to pump fluid through Microbore tubing by means of peristaltic action at very low flow rates It is ideal for sanitizers reagent dispensing analyzers printing systems controlled fee...

Page 4: ...Rotor contains four rollers for minimum pulsation All units operate from an External DC Power Supply The AC models are supplied with a Universal Power Supply which provides a DC output for connection...

Page 5: ...Tubing Retainers Figure 4 3 Once the tubing is in place close the Door and the Occlusion Bed will automatically align itself within the pump Figure 5 4 Insert the tubing into one of the Tubing Retaine...

Page 6: ...wer Supply unit Connect the External Power Supply to the applicable input voltage source and the output of the External Power Supply to the DC input connector on the pump unit Refer to Specifications...

Page 7: ...Tube life is decreased with increased operating speed Priming Pump System The MAX Push Button is used for priming and purging the Pump System When MAX is depressed the pump operates at maximum speed...

Page 8: ...Level Remote Start Stop Contact Closure connection at terminal strip contacts 3 and 4 Construction Dimensions L x W x H 7 0 in x 3 5 in x 3 5 in 17 8 cm x 8 9 cm x 8 9 cm Weight 1 5 pounds 0 68 kg Co...

Page 9: ...r those resulting from product misuse or abuse may be invoiced to you The warranty period for this product is one 1 year from date of purchase PRODUCT RETURN To limit charges and delays contact the se...

Page 10: ...g Use of tubing other than that specified will result in poor pumping performance and or pump system damage and voiding of applicable warranty Available Microbore Autoanalysis Tubing NOTE White indica...

Page 11: ...385 3100 13000 32 0 051 1 30 485 3850 16300 34 0 056 1 42 565 4500 19100 36 0 060 1 52 635 5100 21300 38 0 065 1 65 730 5850 24700 40 0 073 1 85 885 7100 29800 42 0 081 2 06 1050 8500 35200 44 0 090...

Page 12: ...Toll Free 1 800 MASTERFLEX 1 800 637 3739 Outside US Canada 1 847 549 7600 1 847 381 7050 EN809 manufactured by Cole Parmer Instrument Company 28W092 Commercial Avenue Barrington IL 60010 techinfo ma...

Reviews: