10
6. Maintenance
Use safety goggles
Use hearing protection
Use safety gloves
6.1 Regular maintenance
Turn off the closing valve (F) and disconnect the air
supply (G).
- Dismantle anvil(see fig 6.1.a). then
Clean using an air blow gun and soft cloth.
- Dismantle the mandrel (see fig 6.1.b)
Clean using an air blow gun and soft cloth.
- Clean front sleeve (see fig. 6.1.c) using an
air blow gun and soft cloth.
- Lubricate mandrel after reassembly.
6.2
Major maintenance
Every 100.000 cycles tool must be completely
dismantled and all seals and worn parts must