“OL” shown on
the display
“OL” shown on
the display
See
[
1
]
Overrange
Indication
Overrange
Indication
DC CURRENT
Range
400 μA
4000 μA
40 mA
400 mA
4 A
10 A
0.1 μA
1.0 μA
0.01 mA
0.1 mA
1 mA
10 mA
± (1.0% + 7)
± (1.5% + 7)
Resolution
Accuracy
AC VOLTAGE
Input Impedance:
10 MΩ
Frequency Range:
40 – 400 Hz
Response:
Average, calibrated in RMS of sine wave
Max. Allowable Input Voltage:
600 V AC RMS
[
1
]
If the voltage being measured is >600 V, the display may show
the value of the voltage, but the measurement is dangerous.
NOTE:
The 600 V range is accurate from 20 to 100% of range.
Range
4 V
40 V
400 V
600 V
± (0.8% + 5)
± (1.2% + 5)
1 mV
10 mV
0.1 V
1 V
Resolution
Accuracy
14
TECHNICAL SPECIFICATIONS