GENERAL SPECIFICATIONS
Fuse Protection for "INPUT" Terminal Inputs:
400 mA/600 V FAST fuse, Min. Interrupt Rating 10000 A
Fuse Protection for "10A" Terminal Inputs:
10 A/600 V FAST fuse, Min. Interrupt Rating 10000 A
Display:
3 3/4-digit LCD with a max. reading of 3999
Overrange Indication:
"OL" shown on the display
Negative Polarity Indication:
Negative sign " – " shown on the display automatically
Sampling Rate:
About 2 to 3 times/sec
IP degree:
IP 20
Operating Environment:
Temperature: 32 to 104ºF (0 to 40ºC)
Relative Humidity: < 75%
Temperature Coefficient:
0.2 x (specified accuracy) / ºC [< 64ºF (18ºC) or > 82ºF (28ºC)]
Storage Environment:
Temperature: 14 to 122ºF (-10 to 50ºC)
Relative Humidity: < 85% RH
Operating Altitude:
0 – 6560' (0 – 2000 m)
Battery:
9 V battery, 6F22 or equivalent, 1 piece
Low Battery Indication:
" " shown on the display
Size:
7 1/4 x 3 1/2 x 2 7/16" (185 x 89 x 61 mm)
Weight:
About 15 1/2 oz (440 g) (including battery and holster)
12