12
www.mastercool.com
FILLING VACUUM PUMP WITH OIL
:
1.
Open the side maintenance door to access the vacuum pump.
2.
Remove the red cap on top of the vacuum pump.
3.
Empty the oil bottle contents into the vacuum pump.
4.
Verify the oil fill; the oil should meet the oil fill line on the vacuum pump sight
glass.
5.
Replace red cap and clean any excess oil.
6.
Press reset after oil change to zero out the timer.
Pressing NEXT on the bottom of the screen will display last and total refrigerant recovered and the
refrigerant charge.
The values on the left side of the screen will display the last amount of recovered refrigerant and
refrigerant charged. The values on the right side of the screen display the lifetime totals of recovered
refrigerant and refrigerant charged.
•
SETTINGS:
This will allow the user to customize the time/date, language, units and printer of the
COMMANDER machine
o
TIME/DATE:
To set the time and date press the corresponding up or down arrows. Press
update to lock in the selection