Problem: The UTC time (&/or date ) is incorrect
There are several potential failure points:
•
invalid or missing time code source,
•
date/year overwrite function for non-date encoded time code may be enabled improperly,
•
battery may need replacement (see the previous problem item)
•
an NTP client or Windows local time zone configuration may be misleading you.
Verify that your time code source is generating the UTC referenced time and date that you expect, and that this time code
format is at an acceptable signal level and quality that can be detected at the receiver (input to the NTP100-TC). Please see
the NTP100-TC specifications for details.
If you have a time code source from an alternate vendor, be sure that your time code actually contains encoded date
information to the Leitch or IEEE1344 time code formats. For SMPTE-type time codes the date must be encoded to the
Leitch
TM
specification and, for IRIG-B/B(1) time code format, to the IEEE 1344 specification. Verify through your master
clock’s documentation that date encoding is both supported and enabled.
If you are using an acceptable UTC time code source with date encoded time code, ensure that the time/date overwrite
function of the NTP100-TC is not enabled.
If your time code source is making daylight savings time adjustments (during DST) or time zone offsets these must be
functions must be disabled. The NTP100-TC only accepts and decodes UTC referenced time code.
If you are using an NTP client or the date/time display such as on a Windows system, this may provide misleading
information as these may be configured to display local time zone and daylight saving time information. This is configured
through the Date/Time applet in the Control Panel. Use the WinDiscovery or Telnet interface or a system with the time zone
and DST disabled. Confirm the time using the front panel LED display of the NTP100-TC.
A Time Code Reader Card with a
Time Code Viewer
utility or a time code display are useful diagnostic tools in making these
determinations regarding the source. These items are available for separate purchase from Masterclock, Inc.
Masterclock,Inc also provides, for separate purchase, date encoded time code sources such as time code generators,
oscillators, and converters to industry standard time code formats which can be used directly with the autodetection circuitry
of the NTP100-TC. Please contact Masterclock, Inc. to inquire about available date-encoded time code sources.
If these troubleshooting tips do not solve your problem, contact technical support at
or call (636)