Master CLOUD SYNCRO 230V Instruction Manual Download Page 9

 

Page 9 

 

J. 

Check  that  the  exit  on  the  chain  is  perfectly  aligned 
with  the  bracket.  If  the  chain  is  not  aligned  with  the 
bracket,  loosen  the  fixing  screws  and  reposition  the 
bracket correctly. 

K. 

Check  all  electrical  connections  with  the  diagram  on 
the label attached to the lead.  

L. 

Carry  out  a  complete  check  of  opening  and  closure  of  
the  window.  Once  the  closure  phase  has  been 
completed,  check  that  the  window  frame  is  completely 
closed by checking the pressure on the weather strips. 

 

 

Figure 5 

M. 

On  re-entry  the  actuator  limit  switch  functions  automatically.  The  device  exerts  a 
traction force of over 300 N to guarantee perfect sealing up of the weather strips. 

8.2.  Assembly on transom window 

Aside  the  drawing  of  specific  application  using 
accessories  provided.  For  different  mountings, 
please contact manufacturer.
 

A. 

Before  starting,  check  that  there  are  at  least  two 
mechanical  compass  safety  stops  or  other  form  of 
stops  connected  to  the  frame,  and  ensure  that  the 
stops  can  prevent  any  accidental  fall  of  the  window. 
Your safety is at hand. 

B. 

Divide the frame in 3 parts and trace 2 “X”. 

C. 

Select the correct form of brackets (Fig. 6). 

D. 

Attach  the  template  to  the  window  frame  (fixed  part) 
and  line  axis  up  with  the  centre  line “X”  traced  earlier 
(Fig. 7). Warning: for window frames not on the same 
plane, cut the part of the template coloured in grey and 
fix  this  to  the  moveable  part  of  the  window  frame, 
taking care to keep it in the same position. 

E. 

Bore holes in the window frame at the points indicated 
on the template (Fig. 8). 

F. 

Assemble the two brackets with the distancer (to help 
position correctly. Once it has served its purpose it can 
be removed).  Mount  the  supports onto the  frame  with 
the 

appropriate 

screws 

provided. 

Check 

that 

everything is aligned both horizontally and vertically. 

G. 

Mount  the  bracket  for  outward  opening  windows  onto 
the moveable part of the frame in accordance with the 
markings indicated on the template. 

H. 

Complete  assembly  of  the  chain  terminal  with  the 
rapid  release  hook  inserted  onto  the  provided  pin 
Ø4x32 in median position (Fig. 9). 

I. 

Mount  the  actuator  onto  the  brackets  by  inserting  the 
two openings at each side onto the corresponding pins 
on the brackets. 

 

 

Inward application – transom 

window 

 

Figure 6 

 

Figure 7 

 

Figure 8 

Summary of Contents for CLOUD SYNCRO 230V

Page 1: ...Third edition 2014 01 CHAIN OPERATED ACTUATOR ____ CLOUD SYNCRO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ OR 24VDC INSTRUCTION MANUAL ENGLISH...

Page 2: ...ves conformity Contents 1 Safety indications 3 1 1 Formulas and recommendations for installation 4 1 2 Calculation of opening closure force 4 2 Maximum opening according to height of sash 4 3 Use of C...

Page 3: ...installation The manufacturer must be consulted for any other application Installation of the device must be carried out in accordance with the instructions set out by the manufacturer Failure to foll...

Page 4: ...sh only C cm Opening stroke actuator stroke H cm Height of the mobile sash For horizontal light domes or skylights F 0 54 x P Eventual weight of snow or wind on the cupola should be calculated separat...

Page 5: ...the one which reports actuator technical data Electrical feeding cable which is with 5 wires 3 blue black brown 2 white red for 230V version and with 5 wires 3 numbered 1 2 3 2 white red for 24V versi...

Page 6: ...charge Dimensions 386 5x59x37 Weight 1 180 Kg 1 150 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuator...

Page 7: ...ominal charge Cable section Actuator using 24 V 230V 4 00 mm2 1 000 m 3 000 m 2 50 mm2 750 m 2 200 m 1 50 mm2 450 m 1 350 m 0 75 mm2 160 m 500 m 0 50 mm2 130 m 400 m 8 Assembly These indications are i...

Page 8: ...Fig 3 Warning for window frames not on the same plane cut the part of the template coloured in grey and fix this to the moveable part of the window frame taking care to keep it in the same position D...

Page 9: ...safety is at hand B Divide the frame in 3 parts and trace 2 X C Select the correct form of brackets Fig 6 D Attach the template to the window frame fixed part and line axis up with the centre line X...

Page 10: ...ompletely closed by checking the pressure on the weather strips N On re entry the actuator limit switch functions automatically The device exerts a traction force of over 300 N to guarantee perfect se...

Page 11: ...t least one test manoeuvre In case of error the setting can be repeated in order to obtain the desired stroke 10 2 Limit switches at closure The limit switch at closure is automatic electronically ope...

Page 12: ...with one another NOTE In the case of just 2 actuators they are already factory set if there are more than 2 or in the event of replacements follow the instructions below Ensure that all the connectio...

Page 13: ...ral synchronism error Check the settings of the dip switches or repeat the procedure for alignment and address acquisition 11 Checking for correct assembly Check that the window has closed completely...

Page 14: ...We recommend that the device itself and any accessories packaging etc be sent to a centre for ecological recycling 15 Warranty The Manufacturer guarantees good machine function and undertakes to repla...

Page 15: ...the sticker label with the identification code of the article invalidates the warranty Before the intervention of an authorized technician the buyer has to prove the presence of the original power cab...

Page 16: ...age 16 MASTER S r l s p 37 Conversano Castiglione km 0 7 z i 70014 Conversano Bari Italy C P 81 ITALY 39 080 4959823 Fax 39 080 4959030 http www masteronline biz info masteronline biz I461A 06 07 2015...

Reviews: