Page 9
J.
Check that the exit on the chain is perfectly aligned
with the bracket. If the chain is not aligned with the
bracket, loosen the fixing screws and reposition the
bracket correctly.
K.
Check all electrical connections with the diagram on
the label attached to the lead.
L.
Carry out a complete check of opening and closure of
the window. Once the closure phase has been
completed, check that the window frame is completely
closed by checking the pressure on the weather strips.
Figure 5
M.
On re-entry the actuator limit switch functions automatically. The device exerts a
traction force of over 300 N to guarantee perfect sealing up of the weather strips.
8.2. Assembly on transom window
Aside the drawing of specific application using
accessories provided. For different mountings,
please contact manufacturer.
A.
Before starting, check that there are at least two
mechanical compass safety stops or other form of
stops connected to the frame, and ensure that the
stops can prevent any accidental fall of the window.
Your safety is at hand.
B.
Divide the frame in 3 parts and trace 2 “X”.
C.
Select the correct form of brackets (Fig. 6).
D.
Attach the template to the window frame (fixed part)
and line axis up with the centre line “X” traced earlier
(Fig. 7). Warning: for window frames not on the same
plane, cut the part of the template coloured in grey and
fix this to the moveable part of the window frame,
taking care to keep it in the same position.
E.
Bore holes in the window frame at the points indicated
on the template (Fig. 8).
F.
Assemble the two brackets with the distancer (to help
position correctly. Once it has served its purpose it can
be removed). Mount the supports onto the frame with
the
appropriate
screws
provided.
Check
that
everything is aligned both horizontally and vertically.
G.
Mount the bracket for outward opening windows onto
the moveable part of the frame in accordance with the
markings indicated on the template.
H.
Complete assembly of the chain terminal with the
rapid release hook inserted onto the provided pin
Ø4x32 in median position (Fig. 9).
I.
Mount the actuator onto the brackets by inserting the
two openings at each side onto the corresponding pins
on the brackets.
Inward application – transom
window
Figure 6
Figure 7
Figure 8