Mode of installation 

Selection of actuator stroke 

100 

200 

400 

Light  domes,  skylights  or  vertical  top  hung 
windows opening outwards with frontal assembly 

150 

250 

450 

Top hung windows opening  outwards  with horizontal 
assembly 

200 

300 

500 

Bottom hung windows (motor on frame) 

250 

450 

700 

Bottom hung windows (motor on sash) 

Consult manufacturer 

3. Use of Cloud Syncro 

CLOUD  SYNCRO  chain  actuator  is  provided  with  the  patented  system  for  the 
coordinated synchronization of chain movement. Electronic speed control is completely 
automatic  and  don’t  need  any  external  control  unit;  it  is  sufficient  to  connect  among 
them red and white cables already existent on feeding cable (see scheme on page 10). 

3.1.  How to recognise it 

To recognise on sight chain actuator CLOUD SYNCRO from other actuators of CLOUD 
series, there are only three details: 

  Label with Syncro mark attached near the one which reports actuator 

technical data. 

  Electrical feeding cable which is with 5 wires (3 – blue, black, brown +2 – white, red) 

for  230V~  version  and  with  5  wires  (3  numbered  “1”,  “2”,  “3”  +  2  –  white,  red)  for 
24V

 version. 

  Dip-switch on actuator hip has four switches. 

3.2.  When it has to be mounted 

CLOUD  SYNCRO  chain  actuator  is  mounted  when  are  necessary  two  attach  points 
because  window  is  particularly  heavy  or  large  and  a  single  actuator  doesn’t  allow  the 
perfect frame closure. 
Please  remind  that  force  executed  from  a  single  actuator  is  300N;  so  mounting  two 
actuators the force applied on frame is double. 
Frame movement occurs uniformly, synchronized and coordinated without interruptions 
and/or speed variations of two actuators. 
In  case  of  one  of  the  two  actuators  doesn’t  run  for  any  mechanical  or  electrical 
impediment, the other stops too, guarantying in this way frame integrity. 

4. Accessories 

CLOUD SYNCRO actuator is packed in carton boxes. Each package contains: 

  2 actuators with 2,5 metres lead. 

  Standard support brackets with distancer (A). 

  Template for boring. 

  Small parts packaging. 

Summary of Contents for CLOUD SYNCRO 230V

Page 1: ...Third edition 2014 01 CHAIN OPERATED ACTUATOR ____ CLOUD SYNCRO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ OR 24VDC INSTRUCTION MANUAL ENGLISH...

Page 2: ...ves conformity Contents 1 Safety indications 3 1 1 Formulas and recommendations for installation 4 1 2 Calculation of opening closure force 4 2 Maximum opening according to height of sash 4 3 Use of C...

Page 3: ...installation The manufacturer must be consulted for any other application Installation of the device must be carried out in accordance with the instructions set out by the manufacturer Failure to foll...

Page 4: ...sh only C cm Opening stroke actuator stroke H cm Height of the mobile sash For horizontal light domes or skylights F 0 54 x P Eventual weight of snow or wind on the cupola should be calculated separat...

Page 5: ...the one which reports actuator technical data Electrical feeding cable which is with 5 wires 3 blue black brown 2 white red for 230V version and with 5 wires 3 numbered 1 2 3 2 white red for 24V versi...

Page 6: ...charge Dimensions 386 5x59x37 Weight 1 180 Kg 1 150 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuator...

Page 7: ...ominal charge Cable section Actuator using 24 V 230V 4 00 mm2 1 000 m 3 000 m 2 50 mm2 750 m 2 200 m 1 50 mm2 450 m 1 350 m 0 75 mm2 160 m 500 m 0 50 mm2 130 m 400 m 8 Assembly These indications are i...

Page 8: ...Fig 3 Warning for window frames not on the same plane cut the part of the template coloured in grey and fix this to the moveable part of the window frame taking care to keep it in the same position D...

Page 9: ...safety is at hand B Divide the frame in 3 parts and trace 2 X C Select the correct form of brackets Fig 6 D Attach the template to the window frame fixed part and line axis up with the centre line X...

Page 10: ...ompletely closed by checking the pressure on the weather strips N On re entry the actuator limit switch functions automatically The device exerts a traction force of over 300 N to guarantee perfect se...

Page 11: ...t least one test manoeuvre In case of error the setting can be repeated in order to obtain the desired stroke 10 2 Limit switches at closure The limit switch at closure is automatic electronically ope...

Page 12: ...with one another NOTE In the case of just 2 actuators they are already factory set if there are more than 2 or in the event of replacements follow the instructions below Ensure that all the connectio...

Page 13: ...ral synchronism error Check the settings of the dip switches or repeat the procedure for alignment and address acquisition 11 Checking for correct assembly Check that the window has closed completely...

Page 14: ...We recommend that the device itself and any accessories packaging etc be sent to a centre for ecological recycling 15 Warranty The Manufacturer guarantees good machine function and undertakes to repla...

Page 15: ...the sticker label with the identification code of the article invalidates the warranty Before the intervention of an authorized technician the buyer has to prove the presence of the original power cab...

Page 16: ...age 16 MASTER S r l s p 37 Conversano Castiglione km 0 7 z i 70014 Conversano Bari Italy C P 81 ITALY 39 080 4959823 Fax 39 080 4959030 http www masteronline biz info masteronline biz I461A 06 07 2015...

Reviews: