Master CLOUD SYNCRO 230V Instruction Manual Download Page 3

 

Page 3 

 

1. Safety indications 

 

 

ATTENTION

:

  PLEASE  READ  THE  FOLLOWING  SAFETY  INDICATIONS  CAREFULLY 

BEFORE ATTEMPTING INSTALLATION OF THIS APPLIANCE

.

 THESE INDICATIONS WILL 

HELP  TO  AVOID  CONTACT  WITH  ELECTRICAL  CURRENT

,

  INJURY  AND  OTHER 

ACCIDENTS

.

 PLEASE KEEP THIS MANUAL FOR FUTURE CONSULTATION

The CLOUD SYNCRO chain operated actuator has been designed exclusively for moving 
windows.  Any  use  of  the  actuator  for  applications  other  than  those  indicated  must 
previously  be  authorized  by  the  manufacturer  upon  technical  verification  of  the 
application
.  

Carefully observe the followings safety indications. 

  The device must only be installed by competent and qualified technical staff.  

  After removing all packaging, please verify that all parts of the appliance are present.  

  Any plastic bags, polystyrene, or small metallic parts such as  nails, clips, etc. must be 

stored out of the reach of children as they constitute potential sources of danger. 

  Before  connecting  the  appliance  to  the  electricity  supply,  check  that  the  electricity 

supply  in  use  has  the  same  characteristics  as  those  indicated  on  the  technical  data 
label on the device. 

  This  appliance  is  destined  exclusively  for  the  use  for  which  it  has  been  designed  and 

the manufacture cannot be held responsible for any damages incurred by improper use.  

  The  chain  operated  actuator  has  been  designed  for  the  exclusive  purpose  of  internal 

installation. The manufacturer must be consulted for any other application.  

  Installation of the device must be carried out in accordance with the instructions set out 

by the manufacturer. Failure to follow these instructions could compromise safety.  

  Electricity supply installation must be carried out in accordance with regulations in force. 

  To  ensure  effective  separation  from  the  electricity  grid,  we  suggest  installation  of  a 

temporary  approved  type  bipolar  switch  (push  button).  A  multi-pole  main  switch  with 
minimum contact opening of 3 mm should be installed at the start of the command line. 

  Never  clean  the  device  with  solvents  or  jets  of  water.  Never  immerse  appliance  in 

water. 

  Eventual  repairs  must  only  be  carried  out  by  qualified  staff  at  a  service  centre 

authorized by the manufacturer. 

  Always  require  exclusive  use  of  original  spare  parts.  Failure  to  comply  with  this 

stipulation could compromise safety and forfeit warranty benefits for the device. 

  In  the  event  of  trouble  or  doubts,  please  refer  to  your  trust  retailer  or  directly  to 

producer. 

WARNING 

 

Risk of injury in the event that the window should fall on outward opening window 
frames.  A  safety  system  should  be  mounted  onto  the  window  to  guard  against 
falls. This system should be able to withstand at least three times the total weight 
of the window. 

 

This  device  may  cause  injury  by  crushing  or  dragging.  During  function,  when  the 
actuator closes the frame, it applies a pressure force of 300N against the ledge of 
the casing, and all due measures, care and attention should be taken to avoid any 
crushing of fingers. 

Summary of Contents for CLOUD SYNCRO 230V

Page 1: ...Third edition 2014 01 CHAIN OPERATED ACTUATOR ____ CLOUD SYNCRO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ OR 24VDC INSTRUCTION MANUAL ENGLISH...

Page 2: ...ves conformity Contents 1 Safety indications 3 1 1 Formulas and recommendations for installation 4 1 2 Calculation of opening closure force 4 2 Maximum opening according to height of sash 4 3 Use of C...

Page 3: ...installation The manufacturer must be consulted for any other application Installation of the device must be carried out in accordance with the instructions set out by the manufacturer Failure to foll...

Page 4: ...sh only C cm Opening stroke actuator stroke H cm Height of the mobile sash For horizontal light domes or skylights F 0 54 x P Eventual weight of snow or wind on the cupola should be calculated separat...

Page 5: ...the one which reports actuator technical data Electrical feeding cable which is with 5 wires 3 blue black brown 2 white red for 230V version and with 5 wires 3 numbered 1 2 3 2 white red for 24V versi...

Page 6: ...charge Dimensions 386 5x59x37 Weight 1 180 Kg 1 150 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuator...

Page 7: ...ominal charge Cable section Actuator using 24 V 230V 4 00 mm2 1 000 m 3 000 m 2 50 mm2 750 m 2 200 m 1 50 mm2 450 m 1 350 m 0 75 mm2 160 m 500 m 0 50 mm2 130 m 400 m 8 Assembly These indications are i...

Page 8: ...Fig 3 Warning for window frames not on the same plane cut the part of the template coloured in grey and fix this to the moveable part of the window frame taking care to keep it in the same position D...

Page 9: ...safety is at hand B Divide the frame in 3 parts and trace 2 X C Select the correct form of brackets Fig 6 D Attach the template to the window frame fixed part and line axis up with the centre line X...

Page 10: ...ompletely closed by checking the pressure on the weather strips N On re entry the actuator limit switch functions automatically The device exerts a traction force of over 300 N to guarantee perfect se...

Page 11: ...t least one test manoeuvre In case of error the setting can be repeated in order to obtain the desired stroke 10 2 Limit switches at closure The limit switch at closure is automatic electronically ope...

Page 12: ...with one another NOTE In the case of just 2 actuators they are already factory set if there are more than 2 or in the event of replacements follow the instructions below Ensure that all the connectio...

Page 13: ...ral synchronism error Check the settings of the dip switches or repeat the procedure for alignment and address acquisition 11 Checking for correct assembly Check that the window has closed completely...

Page 14: ...We recommend that the device itself and any accessories packaging etc be sent to a centre for ecological recycling 15 Warranty The Manufacturer guarantees good machine function and undertakes to repla...

Page 15: ...the sticker label with the identification code of the article invalidates the warranty Before the intervention of an authorized technician the buyer has to prove the presence of the original power cab...

Page 16: ...age 16 MASTER S r l s p 37 Conversano Castiglione km 0 7 z i 70014 Conversano Bari Italy C P 81 ITALY 39 080 4959823 Fax 39 080 4959030 http www masteronline biz info masteronline biz I461A 06 07 2015...