Master CLOUD SYNCRO 230V Instruction Manual Download Page 11

 

Page 11 

 

10.  Programming the actuator 

10.1. Limit switches at opening 

The  actuators  leave  the  factory  programmed  and  synchronized  in  pairs,  thus  the  user 
only  needs  to  select  the  desired  stroke.  It  is  recommended  that  you  check  to  ensure 
that all the chains are in the same position and the actuators are connected properly as 
per  paragraph  9.  In  the  event  the  settings  are  lost,  a  new  synchronization  must  be 
performed according to the procedures described below. The tables below explain the 
meaning of the dip-switches for the Syncro or Solo operating mode (a Syncro machine 
that works individually) and paired with other devices. 

Mode 

DIP-SWITCH No. 3  DIP-SWITCH No. 4 

SOLO 

ON 

OFF 

SYNCRO 

OFF 

OFF 

Three (3) stroke-end positions can be set for the chain in excursion. The setting is done 
by  adjusting  the  dip-switches  No.  1  and  No.  2  appropriately.  The  setting  is  simple, 
immediate and executable at any time, and it is achieved by operating on the levers of 
the dip-switches as shown in the table below. 

STROKE-END 

DIP-SWITCH 

No. 1 

No. 2 

100 mm 

ON 

OFF 

200 mm 

OFF 

ON 

400 mm 

ON 

ON 

After  setting  the  stroke-end,  it  is  recommended  that  you  make  at  least  one  test 
manoeuvre. In case of error, the setting can be repeated in order to obtain the desired 
stroke. 

10.2. Limit switches at closure 

The  limit  switch  at  closure  is  automatic,  electronically  operated  and  cannot  be 
programmed.  The  actuator  stops  when  the  charge  is  absorbed  when  the  window  is 
completely  closed  and  the  weather  stripping  is  completely  depressed,  or  when  the 
charge  absorbed  is  more  than  10%  of  the  nominal  charge.  In  this  case,  at  maximum 
charge  the  actuator  exercises  a  traction  force  of  over  330N.  After  each  closure  or 
intervention  of  the  electrical  protection  mechanism,  the  chain  moves  in  the  opposite 
direction  for  around  1  mm.  This  is  to  loosen  the  tension  of  the  mechanical  parts  and 
gives  correct  pressure  to  the  weather  stripping.  When  the  window  frame  is  closed, 
check that the chain terminal is at least a couple of millimetres away from the actuator 
body. This ensures proper closure for the window and ensures all weather stripping is 
sealed.  If  the  chain  terminal  is  not  positioned  correctly  there  is  no  guarantee  that  the 
window  will  close  completely.  Check  that  attachments  and  support  brackets  are  firmly 
fixed to the window frame and that all screws have been correctly tightened. 

10.3. Setting for SOLO operation of a Syncro 

  Ensure that all the connections of the wires have been made correctly. 

Summary of Contents for CLOUD SYNCRO 230V

Page 1: ...Third edition 2014 01 CHAIN OPERATED ACTUATOR ____ CLOUD SYNCRO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ OR 24VDC INSTRUCTION MANUAL ENGLISH...

Page 2: ...ves conformity Contents 1 Safety indications 3 1 1 Formulas and recommendations for installation 4 1 2 Calculation of opening closure force 4 2 Maximum opening according to height of sash 4 3 Use of C...

Page 3: ...installation The manufacturer must be consulted for any other application Installation of the device must be carried out in accordance with the instructions set out by the manufacturer Failure to foll...

Page 4: ...sh only C cm Opening stroke actuator stroke H cm Height of the mobile sash For horizontal light domes or skylights F 0 54 x P Eventual weight of snow or wind on the cupola should be calculated separat...

Page 5: ...the one which reports actuator technical data Electrical feeding cable which is with 5 wires 3 blue black brown 2 white red for 230V version and with 5 wires 3 numbered 1 2 3 2 white red for 24V versi...

Page 6: ...charge Dimensions 386 5x59x37 Weight 1 180 Kg 1 150 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuator...

Page 7: ...ominal charge Cable section Actuator using 24 V 230V 4 00 mm2 1 000 m 3 000 m 2 50 mm2 750 m 2 200 m 1 50 mm2 450 m 1 350 m 0 75 mm2 160 m 500 m 0 50 mm2 130 m 400 m 8 Assembly These indications are i...

Page 8: ...Fig 3 Warning for window frames not on the same plane cut the part of the template coloured in grey and fix this to the moveable part of the window frame taking care to keep it in the same position D...

Page 9: ...safety is at hand B Divide the frame in 3 parts and trace 2 X C Select the correct form of brackets Fig 6 D Attach the template to the window frame fixed part and line axis up with the centre line X...

Page 10: ...ompletely closed by checking the pressure on the weather strips N On re entry the actuator limit switch functions automatically The device exerts a traction force of over 300 N to guarantee perfect se...

Page 11: ...t least one test manoeuvre In case of error the setting can be repeated in order to obtain the desired stroke 10 2 Limit switches at closure The limit switch at closure is automatic electronically ope...

Page 12: ...with one another NOTE In the case of just 2 actuators they are already factory set if there are more than 2 or in the event of replacements follow the instructions below Ensure that all the connectio...

Page 13: ...ral synchronism error Check the settings of the dip switches or repeat the procedure for alignment and address acquisition 11 Checking for correct assembly Check that the window has closed completely...