background image

 

 

Third edition - 2014/01 

 

 
 
 

CHAIN OPERATED ACTUATOR  

____

   

CLOUD SYNCRO 

 
 

F

ORCE 

300

 

N

  

-

  MAXIMUM STROKE  

400

 MM

 

E

LECTRICAL FEEDING 

230VAC

 

50

 

H

Z

 

OR 

24V

DC

 

 
 
 

 

 
 
 
  

INSTRUCTION MANUAL 

 

 

 

 

 

 

 

 

ENGLISH

 

 

Summary of Contents for CLOUD SYNCRO 230V

Page 1: ...Third edition 2014 01 CHAIN OPERATED ACTUATOR ____ CLOUD SYNCRO FORCE 300 N MAXIMUM STROKE 400 MM ELECTRICAL FEEDING 230VAC 50 HZ OR 24VDC INSTRUCTION MANUAL ENGLISH...

Page 2: ...ves conformity Contents 1 Safety indications 3 1 1 Formulas and recommendations for installation 4 1 2 Calculation of opening closure force 4 2 Maximum opening according to height of sash 4 3 Use of C...

Page 3: ...installation The manufacturer must be consulted for any other application Installation of the device must be carried out in accordance with the instructions set out by the manufacturer Failure to foll...

Page 4: ...sh only C cm Opening stroke actuator stroke H cm Height of the mobile sash For horizontal light domes or skylights F 0 54 x P Eventual weight of snow or wind on the cupola should be calculated separat...

Page 5: ...the one which reports actuator technical data Electrical feeding cable which is with 5 wires 3 blue black brown 2 white red for 230V version and with 5 wires 3 numbered 1 2 3 2 white red for 24V versi...

Page 6: ...charge Dimensions 386 5x59x37 Weight 1 180 Kg 1 150 Kg Any information reported in this table is not binding and may be susceptible to variations without notice 6 Label data and markings The actuator...

Page 7: ...ominal charge Cable section Actuator using 24 V 230V 4 00 mm2 1 000 m 3 000 m 2 50 mm2 750 m 2 200 m 1 50 mm2 450 m 1 350 m 0 75 mm2 160 m 500 m 0 50 mm2 130 m 400 m 8 Assembly These indications are i...

Page 8: ...Fig 3 Warning for window frames not on the same plane cut the part of the template coloured in grey and fix this to the moveable part of the window frame taking care to keep it in the same position D...

Page 9: ...safety is at hand B Divide the frame in 3 parts and trace 2 X C Select the correct form of brackets Fig 6 D Attach the template to the window frame fixed part and line axis up with the centre line X...

Page 10: ...ompletely closed by checking the pressure on the weather strips N On re entry the actuator limit switch functions automatically The device exerts a traction force of over 300 N to guarantee perfect se...

Page 11: ...t least one test manoeuvre In case of error the setting can be repeated in order to obtain the desired stroke 10 2 Limit switches at closure The limit switch at closure is automatic electronically ope...

Page 12: ...with one another NOTE In the case of just 2 actuators they are already factory set if there are more than 2 or in the event of replacements follow the instructions below Ensure that all the connectio...

Page 13: ...ral synchronism error Check the settings of the dip switches or repeat the procedure for alignment and address acquisition 11 Checking for correct assembly Check that the window has closed completely...

Page 14: ...We recommend that the device itself and any accessories packaging etc be sent to a centre for ecological recycling 15 Warranty The Manufacturer guarantees good machine function and undertakes to repla...

Page 15: ...the sticker label with the identification code of the article invalidates the warranty Before the intervention of an authorized technician the buyer has to prove the presence of the original power cab...

Page 16: ...age 16 MASTER S r l s p 37 Conversano Castiglione km 0 7 z i 70014 Conversano Bari Italy C P 81 ITALY 39 080 4959823 Fax 39 080 4959030 http www masteronline biz info masteronline biz I461A 06 07 2015...