STARTING THE HEATER
Before turning on the heater and therefore before attaching it
to the mains power supply, check that the characteristics of the
mains power supply are the same as those indicated on the
identification label.
WARNING:The electric power cable of the heater must
be earthed and must have a differential magnetothermal
switch.The electric plug must be connected to a socket
which has a disconnecting switch.
To turn on the machine, do the following:
• Flip switch 1 (Fig. 2) to the position with the symbol: ON – the
fan comes on and after several seconds the heater starts bur-
ning.
The first time the heater is used, or after the fuel circuit has been
completely drained, the flow of fuel oil to the nozzle may be in-
sufficient and may activate the flame cut out mechanism, which
will turn off the heater;if this happens, wait for about a minute
and then press the reset button 2 (Fig. 2) to start the machine
again.
The first steps to take if the machine does not work are the
following:
1. Check that there is fuel in the tank;
2. Press the reset button 2 (Fig.2);
3. If the heater still does not work, consult the “TROUBLESHO-
OTING”guide.
TURNING OFF THE HEATER
To turn off the machine, move switch 1 (Fig. 2) to the “OFF” po-
sition The flame will go off and the fan will continue to function
until the combustion chamber has cooled down completely.
SAFETY DEVICES
The heater is equipped with an electronic device to control the
flame.If there is an anomaly in the functioning, the machine will
be turned off and the reset button light 2 (Fig.2) will come on.
An over-heating thermostat cuts in and shuts off the fuel supply
if the heater overheats:the thermostat resets itself automatically
when the temperature in the combustion chamber diminishes
and reaches the maximum permitted value.
Before turning the heater on again, the cause of the overheating
must be identified and removed (for example, a blockage in the
suction orifice and/or of the air flow duct, the non-functioning
of the fan). To turn on the machine again, press the reset but-
ton and repeat the specific instructions outlined in the section
“STARTING THE HEATER”.
MOVING AND TRANSPORTING
THE HEATER
WARNING The following steps must be carried out befo-
re moving the heater: turn the heater off, following the
instructions in the previous section; disconnect the plug
from the power supply and wait for the heater to cool.
Before the generator will be lifted or moved you should be to
ensure that the cap of the tank well stuck.
The generator as a mobile version can be fitted with wheels.
PREVENTATIVE
MAINTENANCE PROGRAMME
To ensure that the heater continues to work properly, it is neces-
sary to periodically clean the combustion chamber, the burner
and the fan.
WARNING The following steps must be carried out befo-
re servicing the heater: turn the heater off, following the
instructions in the previous section; disconnect the plug
from the power supply and wait for the heater to cool.
Every 50 hours of use it is necessary to:
• Dismantle the filter cartridge, remove it and clean it with clean
fuel oil.
• Remove the exterior cylindrical casing and clean the inside
and the blades of the fan.
• Check the condition of the cables and the high voltage connec-
tions on the electrodes.
• Dismantle the burner, clean the parts, then clean the electro-
des and regulate them to the distance indicated in (Fig. 3-4)
the electrode regulation diagram.