![Master Power GreenE 3.68K Installation, Operation & Maintenance Manual Download Page 35](http://html1.mh-extra.com/html/master-power/greene-3-68k/greene-3-68k_installation-operation-and-maintenance-manual_1737618035.webp)
68
❺
BMS INFO
4.5 Statistics
❶
Time accounting
You can query the following information about the five
battery packs: BMS program version, Whether the battery
pack is online, Number of battery pack cycles, Heating film
state, heating film open or closed, Charging MOS tube
status: charging MOS off or on, Discharge MOS tube
status: discharge MOS off or on , Battery pack BMS alarm
code , Battery pack BMS protection code, BMS fault code
of the battery pack.
Interface
Explanation
-PACK INFO-
1: PACK 1
2: PACK 2
3: PACK 3
4: PACK 4
5: PACK 5
VERSION:
1.012
STATUS:
ONLINE
CYCLE CNT:
15
HEAT FILM:
OFF
CHAR MOSFET:
OFF
DISC MOSFET:
OFF
WARN CODE:
12
PROTECT:
32
FAULT CODE:
14
This interface is used to select statistics items.
Press UP/DOWN button to move corresponding options.
Press Enter to enter the selected menu.
Press ESC button to return to user interface.
There are eight alternative options in total: time
accounting, grid-connection frequency/peak power/power
generation for the day/power generation for the
month/power generation for the year/gross power
generation (refer to 1 to 7).
Interface
Explanation
-STAT-
1: TIME STAT.
2: CONNE.TIMES
3: PEAK POWER
4: E-TODAY
5: E-MONTH
6: E-TEAR
7: E-TOTAL
Operation length of inverter (hours).
Grid-connection length (hours).
Press ESC button to return to statistics interface.
Interface
Description
-Time-
RUN:
5
GRID:
0
UNIT:
HOUR
User Manual
69
❷
Grid-connection frequency
❸
Peak power
❹
The day
❺
The month
This interface displays grid-connection frequency of the
inverter.
Press ESC button to return to statistics interface.
Interface
Description
-CONNE.TIMES-
TIMES:
0
This interface displays power peak in history and for the
day.
Press ESC button to return to statistics interface.
Interface
Description
-PEAK POWER-
HISTORY:
5000
TODAY:
0
UNIT:
W
This interface displays power generation for the day
(
kWh).
PV power generation.
Electric energy selling to grid.
Electric energy buying from grid.
Power consumption of load.
Interface
Description
-E-TODAY-
PV:
0.0KWH
METER:
0.0KWH
GRID:
0.0KWH
LOAD:
0.0KWH
CHARG:
0.0KWH
DISCH:
0.0KWH
This interface displays power generation for the month
(kWh).
PV power generation.
Electric energy selling to grid.
Electric energy buying from grid.
Power consumption of load.
Interface
Description
-E-MONTH-
PV:
0.0KWH
METER:
0.0KWH
GRID:
0.0KWH
LOAD:
0.0KWH
User Manual