![Master Power GreenE 3.68K Installation, Operation & Maintenance Manual Download Page 24](http://html1.mh-extra.com/html/master-power/greene-3-68k/greene-3-68k_installation-operation-and-maintenance-manual_1737618024.webp)
1. Working mode
After completing the setup of peak load shifting mode, the time for charging and discharging also
needs to be set.
Time setup
46
4.3 Setting
4.3.1 System setting
This interface is used for various information inquiry
options.
Press UP/DOWN button to move the corresponding
options.
Press ENTER to enter the selected menu.
Press ESC button to return to the user interface.
There are 13 options in total, including system mode,
battery parameters, grid standard, operation parameters,
485 address, 485 baud rate, language display, LCD
backlight, date/time, clear history, password setting and
maintenance, and factory setting.
Interface
Explanation
-SETUP-
1: SYS SETTING
2: BAT SETTING
3: GRID STD
4: RUN SETTING
5: 485 ADDRESS
6: BAUD RATE
7: LANGUAGE
8: BACKLIGHT
9: DATE/TIME
10: CLEAR REC
11: PASSWORD
12: MAINTENANCE
13: FCTRY RESET
14: AUTO TEST
This interface is used to access system information.
Press UP/DOWN button to move corresponding options.
Press ENTER to enter the selected menu.
Press ESC button to return to the setting interface.
There are 13 options in total, including working mode, PV
input type, anti-reflux enable, DRM enable, EPS enable,
remote controlled enable, boot delay time (see from 1 to
16).
Interface
Explanation
-SYS SETTING-
1: WORK MODE
2: PV INPUT
3: ZERO EXPORT
4: DRM ENABLE
5: EPS ENABLE
6: REMOTE CTRL
7: START DELAY
8: CEI SPI CTRL
9: GFCICHK ENB
10: DISC MODE
11: DISCHGDEPTH
12: GENERATOR
13: CT OR METER
14: AC COUPLE
15: CT Directio
16: ISLAND
User Manual
47
This interface is used to opt for the working mode.
After selecting the three modes, the restart interface will
be entered.
Press ESC button to return to setting interface.
Interface
Explanation
-WORKE MODE-
1: SELF CONSUME
2: PEAK SFT
3: BATPRIORITY
1. DISABLE
2. ENABLE
After selecting Allow, the charging time setting page is
displayed.
Interface
Explanation
-SELF CONSUME-
1: DISABLE
2: ENABLE
1. Self-consumption mode disables grid charging: Battery
pack can only be charged by PV.
2. Self-consumption mode enables grid charging: Grid
charges battery pack until MAX SOC during set time.
Interface
Explanation
-CHARGE TIME-
00:00-23:59
MAX SOC: 100
%
This interface is used to set the time-1 of peak load
shifting.
Press UP/DOWN button to change the value.
Press ENTER to confirm.
Press ESC button to return.
This interface is used to set the time-2 of peak load
shifting.
Press UP/DOWN button to change the value.
Press ENTER to confirm.
Press ESC button to return.
Interface
Description
CHA STAR1: 00:00
CHA REND1: 00:00
DIS START1: 00:00
DISC END1: 00:00
CHA STAR2: 00:00
CHA REND2: 00:00
DIS START2: 00:00
DISC END2: 00:00
User Manual