16
... the temperature cut-out
actuates
Coil too hot because power
intake too high
Eliminate sluggishness or pump
blockage
If motor defective:
This
work may only be done at
the factory
Have motor repaired
Temperature of pumped
mediums too high (over
45°C)
Observe temperature limits
... the alarm sounds
Intake exceeds pumping
speed of pump
Reduce intake, use more powerful
pump if necessary
Malfunction on float
Make float accessible and clean
Pump blocked
Remove foreign body from casing
and/or running wheel
Motor defective
This work may only be
done at the factory
Have motor repaired
Pressure line blocked
Clean pressure line
6
Spare parts list
Pos.
Description
STANDARD
S
SA
3
Strainer
02 00 070
32
Guide clamp (rotary
hinge)
02 00 080
40
Non-return flap
02 00 023
41
Screw-in element
02 00 090
48
Trenched washer
02 00 236
49
Floater
02 00 205
7
Accessories
For the pump of this series is a float-switch available for backfitting (only for model STANDARD), non-return
flap (serial at models “S” , “SA”, and “F”), residual-current-operated protective device (RCD), mooring rope,
couplings (e.g. Geka, STORZ C) and much more. Ask our customer care for more details.
8
Disposal
This product and parts of it must be disposed according local, applicable regulations or to be returned to the
manufacturer.