Masport PG36-3 Gas Inbuilt
20
Conversion Kit for NG to LPG Model #516-969
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Burner Orifice
Conversion Kit 516-969 Contains:
Qty. Part #
Description
1 904-390
Burner Orifice #52
1 908-528
Red "LPG" label
2 908-255
Label "Converted to LPG"
1 918-334
Instruction Sheet
1 910-920
LPG Pilot Orifice
1) Shut off the gas supply and unplug the
power cord.
2) Carefully remove the glass, logs and lava
rock.
3) Remove burner.
4) Remove burner orifice with a 1/2" wrench
and discard. Use a wrench to hold on to the
elbow behind the orifice.
5) Reinstall new burner orifice LPG stamped
#52 and tighten.
16) Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
17) Replace the yellow "NG" label with the red
"LPG" label.
18) Disconnect the 6 pin Molex connector and
carefully pull out the control box.
NOTE: The control box is held in place with
velcro.
Control Box
Cover
Antenna
19) Remove the control box cover by undoing
the 3 screws. Maneuver through antenna.
Jumper Location
Jumper
6) Remove the rear log burner tray.
7) Remove the 2 screws which secure the
pilot.
Rear Log Burner Tray
8) Lift the pilot assembly and remove the pilot
tube from the pilot holder using a 11mm
wrench.
9) Remove the NG pilot orifice and replace it
with the LPG orifice.
Pilot
Assembly
Pilot
Orifice
Pilot
Extrusion
Tube
Pilot
Tube
13) Adjust the burner aeration setting to fully
open and replace the burner.
14) Open the bottom louvre.
15) Remove the front cover by undoing the 2
screws.
Front Cover
6-pin Molex
Connector
20) Remove the jumper using a plier.
INSTALLATION
10) Install the pilot tube to the pilot assembly.
11) Place the pilot assembly over the pilot extru-
sion tube and secure it with 2 screws.
12) Replace the rear log burner tray.