background image

Model: DDU-TM-44/46 or DDU-44/46

 

 

 

Doc. Ref. no. : - m06c/om/101 

Issue no. 04 

 

 

Page 29 of 36 

 

  

User’s Manual

                                                                                                                  

 

                                                             7.  OPERATION INFORMATION 

7.1 Operation as Time/Date Display [DDU-TM-44/46 or DDU-44/46]  

1.  Insert the power cord into an appropriate connector inside the clock.  
2.  Upon  Power  up  of  DDU-TM-44/46  or  DDU-44/46,  The  Unit  display  Slave  id  Then  if  unit  is  wireless 

input model then it display the RF receive channel and transmit channel that you are set. Then it will 
start  displaying  time/date  from  internal  RTC  otherwise  it  will  start  displaying  time/date  from  internal 
RTC.  After  synchronization  with  master  clock,  it  will  take  &  display  the  time/date  of  master  device. 
DDU-TM-44/46  or  DDU-44/46  clock  will  start  display  RF  receive  channel  0  and  then  start  from 
00:01:00  and  01/01/15,  during  first  time  Power  ON  &  run  on  internal  RTC  until  synchronizes  with 
master clock.  
 

3. 

RS232/485 Signal as Input:

  

There is auto frame detection mode is given in DDU-TM-44/46 or DDU-44/46, so no configuration is 
required  for  frame  input  selection.  Connect  a  source  of  Serial  Communication  of  GPS  to  the  input 
serial  connector  of  DDU-TM-44/46  or  DDU-44/46.The  time  should  appear  on  the  display  within  60 
seconds  of  application  of  time  code. If  the  time  code  signal  is  lost  or  disconnected,  then  DDU-TM-
44/46 or DDU-44/46 will continue to display time based on its internal RTC, until the time code signal 
is returned.  
 

4. 

Wireless Input:  

 

Set RF receive channel in DDU-TM-44/46 or DDU-44/46, on which channel Wireless master 
transmitting the time code signals. You can set receive channel between 0-9 and auto. Auto 
option  will  scan  automatically  on  which  channel  wireless  transmitter  transmitting  the  time 
code frames. 

 

If you are select Auto mode in RF receive channel and then after unit power on it will display 
RF receive channel which unit previous lock in auto mode. 

 

DDU-TM-44/46  or  DDU-44/46  will  catch  the  signal  from  around  100  meters  area  with 
obstacles in case of master to slave communication or 50 meters in case of DDU-TM-44/46 
or DDU-44/46 to DDU-TM-44/46 or DDU-44/46 slave communication. 

 

DDU-TM-44/46  or  DDU-44/46  has  option  of  Re-transmission  of  received  signals,  set  RF 
transmit  channels  between  0  to  9,  and  DDU-TM-44/46  or  DDU-44/46  will  transmit  the 
received signals on set channel, for increasing the Range. If you do not want to re-transmit 
then set no option in RF-T key configuration menu. 

 

For Wireless Input Refer 

[see Communication Guidelines Section]

 

 

5. 

RS232/485 Signal as Output:

  

 

If  you  are  selected  to  transmit  NMEA

-

0183[RMC]  Format

 

output

 

frame  only  the  Time  and 

Data field is Present and remaining Data Field transmitting as Zeros from the DDU-TM-44/46 
or DDU-44/46 with help of selection in retransmitting configuration. 

 

If  you  are  selecting 



  and 



  option  in  retransmission  configuration  then  it  working  as 

output terminal. 
 

NOTE: If DDU-TM-44/46 or DDU-44/46 is in sync using Serial [RS232/RS485] than do not use 
Serial [RS232/RS485] for Retransmission. 
 

6. 

Wireless Output: 

 

If you are selected to transmit Wireless

 

output

 

frame from the DDU-TM-44/46 or DDU-44/46 

with help of selection in retransmitting configuration. 

 

If  you  are  selecting 



  and 



  option  in  retransmission  configuration  then  it  Transmitting 

Wireless output Frame. 

 

Then you have to select RF transmit channel which for Transmitting Wireless Output Frame. 
This unit work as Master Clock for other unit which is Synchronize with this Unit in the range 
of it. 

7.  If the clock is unable to achieve a time code lock see the section entitled 

Troubleshooting Tips

8.  For  Serial  Communication  time  codes  date  must  be  encoded  to  the  standard  specification.  These 

specifications  are  also  supported  by 

Masibus

  Master  Clock  systems 

[see  Communication 

Guidelines Section 8.2]

.  

Summary of Contents for DDU-44

Page 1: ...ion And Instrumentation Pvt Ltd B 30 GIDC Electronics Estate Sector 25 Gandhinagar 382044 Gujarat India 91 79 23287275 79 91 79 23287281 82 Email support masibus com Web www masibus com DDU 44 46 DDU...

Page 2: ...l Output 8 3 FRONT PICTURE 9 3 1 DDU 44 DDU TM 44 IP20 Front views 9 3 2 DDU 44 DDU TM 44 IP20 SS Front Plate Front views 10 3 3 DDU 46 DDU TM 46 IP20 Front views 11 3 4 DDU 46 DDU TM 46 IP20 SS Front...

Page 3: ...Manual 7 1 Operation as Time Date Display DDU TM 44 46 or DDU 44 46 29 8 COMMUNICATION GUIDELINES 31 8 1 Serial Time Frame Input 31 8 2 Wireless Time Frame Input 32 8 3 Wireless Configuration Frame I...

Page 4: ...9 Mounting detail for 4 4 Digits 460mm x 175mm x 70mm Enclosure Wall Mount 13 Figure 10 Mounting detail for 4 4 Digits 500mm x 215mm x 79mm Enclosure Wall Mount SS Front 14 Figure 11 Mounting detail...

Page 5: ...munication information and if Serial communication based unit is selected then ignore RF related information Trademarks Our product names or brand names mentioned in this manual are the trademarks or...

Page 6: ...nt Enclosure is available with SS SS 304 Front Plate without Conceal Box with Wall Mount Key Holes Safety Precautions The product and the instruction manual describe important information to prevent p...

Page 7: ...Line of Site Range Approx 600 meters depends on site conditions 100meters with obstacles 50 meters with obstacles for slave to slave Serial Communication RS232 RS485 Protocols NMEA 0183 RMC NGTS T For...

Page 8: ...als Secondary terminals indicate RS232 485 Insulation resistance 20M or more 500 V DC between power terminals and grounding terminal Input Description Physical Interface Serial RS485 Protocols NMEA 01...

Page 9: ...TM 44 46 or DDU 44 46 Doc Ref no m06c om 101 Issue no 04 Page 9 of 36 User s Manual 3 FRONT PICTURE 3 1 DDU 44 DDU TM 44 IP20 Front views Figure 1 Front View of DDU 44 IP20 Figure 2 Front View of DDU...

Page 10: ...44 46 Doc Ref no m06c om 101 Issue no 04 User s Manual Page 10 of 36 3 2 DDU 44 DDU TM 44 IP20 SS Front Plate Front views Figure 3 Front View of DDU 44 IP20 SS Front Plate Figure 4 Front View of DDU...

Page 11: ...el DDU TM 44 46 or DDU 44 46 Doc Ref no m06c om 101 Issue no 04 Page 11 of 36 User s Manual 3 3 DDU 46 DDU TM 46 IP20 Front views Figure 5 Front View of DDU 46 IP20 Figure 6 Front View of DDU TM 46 IP...

Page 12: ...44 46 Doc Ref no m06c om 101 Issue no 04 User s Manual Page 12 of 36 3 4 DDU 46 DDU TM 46 IP20 SS Front Plate Front views Figure 7 Front View of DDU 46 IP20 SS Front Plate Figure 8 Front View of DDU...

Page 13: ...nal is marked with a label on the product terminals with the following symbol Also insure that Earth Ground of the premises has been done properly Be sure all personnel involved in installation servic...

Page 14: ...there are two mounting Key hole in Bottom Part of Enclosure as shown in below drawing Figure 10 Mounting detail for 4 4 Digits 500mm x 215mm x 79mm Enclosure Wall Mount SS Front For DDU TM 46 DDU 46 W...

Page 15: ...04 Page 15 of 36 User s Manual For DDU TM 46 DDU 46 with SS Front Plate Wall mounting there are two mounting Key hole in Bottom Part of Enclosure as shown in below drawing Figure 12 Mounting detail fo...

Page 16: ...el mount two clamps are used for panel mounting as shown in below image Figure 13 Mounting detail for 4 4 Digits 460mm x 175mm x 70mm Enclosure Panel Mount For DDU TM 46 DDU 46 Panel mount two clamps...

Page 17: ...SS Front Plate as shown in below drawing Figure 15 Mounting detail for 4 4 Digits 500mm x 215mm x 79mm Enclosure Flush Mount 1 Cutout in Wall or Partition Dimension 465 W x 177 H x 85 D 2 DDU TM 44 DD...

Page 18: ...Plate as shown in below drawing Figure 16 Mounting detail for 4 6 Digits 705mm x 215mm x 79mm Enclosure Flush Mount 1 Cutout in Wall or Partition Dimension 670 W x 177 H x 85 D 2 DDU TM 46 DDU 46 Ins...

Page 19: ...Description 1 MSTB Conn 4 pin for RS232 or RS485 RS232 or RS485 serial data input For RS232 7 TX 6 RX 5 GND 4 GND For RS485 7 A 6 B 5 GND 4 GND 8 MSTB Conn 3 pin for Aux PWR 3 L 2 N 1 Earth 5 1 2 Term...

Page 20: ...to the primary side of the line and use a line filter on the secondary side Do not place the primary and secondary power cables close to each other Use repeater after each set of 32 instruments connec...

Page 21: ...DDU TM 44 46 or DDU 44 46 offers facility to the users for configuring communication parameters of serial port Display Format Selection Time Zone Selection Manual Time Set Set Default Parameter Retra...

Page 22: ...Model DDU TM 44 46 or DDU 44 46 Doc Ref no m06c om 101 Issue no 04 User s Manual Page 22 of 36 Figure 21 Display and Key Configuration Detail...

Page 23: ...Model DDU TM 44 46 or DDU 44 46 Doc Ref no m06c om 101 Issue no 04 Page 23 of 36 User s Manual...

Page 24: ...start to display Time in default condition that are set in unit If you are already set RF transmit channel and then after unit power on it will display RF receive channel and RF transmit channel that...

Page 25: ...set the any One Date mode 6 2 3 4 Manual Time Set Configuration S TM Press Enter Key to Enter in Manual Time Set mode it will enter in View mode and shows Current Time on Display Press Enter in View...

Page 26: ...nel Set mode it will enter in View mode and shows Current RF Transmit Channel on Display Press Enter in View mode to enter in Edit mode in Edit mode Set RF Transmit Channel using INC Key Press Enter k...

Page 27: ...urrent configuration of Retransmission Press Enter in View mode to enter in Edit mode in Edit mode set configuration of Retransmission using INC and SHIFT Keys Press Enter key to set the Retransmissio...

Page 28: ...r GPS MC 2 Over Wireless DDU TM 44 46 or DDU 44 46 offers facility to the users for configuring communication parameters of serial port Display Format Selection Time Zone Selection Manual Time Set Set...

Page 29: ...power on it will display RF receive channel which unit previous lock in auto mode DDU TM 44 46 or DDU 44 46 will catch the signal from around 100 meters area with obstacles in case of master to slave...

Page 30: ...isplay which Display Both Time and Date Display Date will be displayed at 18 20 seconds 38 40 seconds and 58 60 seconds These Display settings can be done by Key Configuration There are two Time Forma...

Page 31: ...r ground 245 0 Degrees UTC Date 291206 DDMMYY Magnetic variation Degrees Magnetic variation E East W West Checksum 25 CC Terminator CR LF Non printing characters 8 1 2 NGTS Format The settings for thi...

Page 32: ...channel 0 on DDU TM 44 46 or DDU 44 46 all slave DDU TM 44 46 or DDU 44 46 will get lock which are in range of Wireless Master As shown in figure S1 S2 and S3 are all in range of master so it will be...

Page 33: ...stored RF channel it will try for 9 minutes to sync with last stored channel Till After 9 minutes if it fails to get sync with master or slave it will start RF channel scanning from channel 0 to 9 for...

Page 34: ...d with multi meter This is not the exact voltage level of any signal but this gives ruff idea about signal presence on port 3 The time code being fed to the DDU TM 44 46 or DDU 44 46 must be recognize...

Page 35: ...at is at an acceptable signal level and quality that can be detected at the client side i e DDU TM 44 46 or DDU 44 46 input 2 If you are using in house Time Code verify that the Time Code source is lo...

Page 36: ...ompared to m06bom101 03 1 DDU 46 SS Wall Mount unit image added 2 Power supply range updated in Specification Masibus Automation Instrumentation Pvt Ltd Customer Support Division B 30 GIDC Electronics...