6. CONFIGURATION GUIDELINES
6.1 Default Configuration
A DDU-TM-44/46 or DDU-44/46 ships from the factory with following configuration.
Display Type : Time Display
Time Format : Hour Time Format 24
Date Format : DD.MM
Time Zone Offset : 05:30
Applicable for Serial Input Model:
Baud Rate
: 9600
Stop Bit
: 1
Parity Bit
: None
Applicable for Wireless Input Model:
RFM Receive Channel : 0
Display Unlock Blink
: BL.10
Password
: 0001
Retransmission
: No
Slave ID
: XXXX[Between 0001 to 9998]
Note:
1. Fundamental operation mode (Display Settings) will come in affect immediately of SW change.
Action of CONFIG can be switched during clock operation. No power on/off cycle is required to
change these modes.
2. Default Setting of DDU-TM-46/DDU-46 Same as above configuration but only change in Date
Format. In DDU-TM-46/DDU-46 date Format is DD.MM.YY by Default.
3. Slave ID of Unit is set in Factory once. You can set Slave Id by Entering in Configuration Menu.
Slave ID will not change in Default Condition.
6.2 Key Configuration:
DDU-TM-44/46 or DDU-44/46
offers facility to the users for configuring communication parameters
of serial port, Display Format Selection, Time Zone Selection, Manual Time Set, Set Default Parameter,
Retransmission selection and View Current Settings by Key Configuration.
The communication parameters include baud rate, number of stop bits and parity.
User Can Set Manual Time if no availability of Time Inputs.
The user is free to choose Time Display, Date Display and Both in Alternate Time/Date Display.
User can set any Standard Time Zone Offset, in any Input like Wireless and Serial.
The user can enter the time offset of the time zone, where the unit is to be installed.
Users can set Default all Configuration Parameter and View Current Configuration Parameter using
Key Configuration.
The user can set the Retransmission using RF, Serial or Both.
User can set blinking of Date DP and Time Display Colon in unlock condition.
6.2.1 Run Mode
As Shown in Fig 8 DDU-TM-44/46 or DDU-44/46, will display Time or Date as per
set parameter in Run mode.
6.2.2 Password Mode (PSWD):
To enter in Password mode long press Enter key for 4 Seconds, it will show
PSWD
in Display. Enter Password using UP, Shift and Enter Keys, DDU-TM-44/46 or DDU-
44/46 will enter in Configuration mode and Display
DISP
on Display.