Model: DDU-TM-44/46 or DDU-44/46
Doc. Ref. no. : - m06c/om/101
Issue no. 04
User’s Manual
Page 28 of 36
Press Enter in View mode to enter in Edit mode, in Edit mode set Slave ID using INC
and SHIFT Keys, Press Enter key to set Slave ID.
6.2.3.16 Set Default Configuration (STDF):
Press Enter Key to set the default parameters and Default parameter as per below.
Display Type : Time Display
Time Format : Hour Time Format 24
Date Format : DD.MM
Time Zone Offset : 05:30
Applicable for Serial Input Model:
Baud Rate
: 9600
Stop Bit
: 1
Parity Bit
: None
Applicable for Wireless Input Model:
RFM Receive Channel : 0
Display Unlock Blink
: BL.10
Password
: 0001
Retransmission : No
Slave ID
:XXXX[Between 0001 to 9998]
Note:-
1. Default Setting of DDU-TM-46/DDU-46 Same as above configuration but only change in Date
Format. In DDU-TM-46/DDU-46 date Format is DD.MM.YY by Default.
2. Slave ID of Unit is set in Factory once. You can set Slave Id by Entering in Configuration Menu.
Slave ID will not change in Default Condition.
6.2.4
Configuration command through Master (GPS-MC-2) Over Wireless:
DDU-TM-44/46 or DDU-44/46 offers facility to the users for configuring communication parameters of
serial port, Display Format Selection, Time Zone Selection, Manual Time Set, Set Default Parameter,
Retransmission selection set by Key or configuration Frame Sent by master GPS-MC-2 over
Wireless and View Current Settings by Key Configuration.
Error Message code Can be Display when any Error Found in received Configuration frame from
Master (GPS-MC-2) over Wireless. Show the Table 4 for Error message display code
User can see the Slave ID of Unit in Run Mode by sending reset command through Master(GPS-
MC-2)
If Slave ID does not match with Received Frame then lower digit of second and Lower digit of month
or Year DP Blinking Started for 2 second.
Table 5 Error Message Display Code
Er.01
Display Mode
Er.02
Time Mode
Er.03
Date Mode
Er.04
Time Zone Offset set Mode
Er.05
Baud Set mode
Er.06
Stop set Mode
Er.07
Parity set Mode
Er.08
Retransmission Mode
Er.09
RF Frame Transmit Channel set Mode
Er.10
RF Frame Receive set Mode
Er.11
Unlock Blinking set Mode
Er.12
Slave ID
Er.13
Show Slave ID Error Command
Note:
1) Er.03 code Display in DDU-46 when you will try to set Date Mode YY.MM.DD Format
.