2.9. Call centre notifications 

 

The  mobile  phone  or  call-centre  receives  the  following  event  notifications  by  SMS/GPRS 
messages: 

a.  Device worn/not worn ON/ OFF. 
b.  Device clipped/unclipped. 
c.  Low battery level. 
d.  Very low battery level. 
e.  Battery depleted. 
f.  Battery charger unplugged. 
g.  Battery charge full. 
h.  Battery charge started. 
i.  Panic/fall alarm. 
j.  Security perimeter alarm. 
k.  User GPS location (under request). 
l.  Firmware version (under request). 

 
 
2.10. Remote configuration

 

  

The device can be configured by SMS commands or using the App iFALLDET-C. The following 
features can be configured: 

a.  Battery levels. 
b.  Alarm cancellation. 
c.  Telephone numbers and addresses for communications. 
d.  Password. 
e.  Security perimeter. 
f. 

GPS position request. 

g.  Activate/deactivate fall detection. 
h.  Activate/deactivate the panic button. 
i. 

Restart the device. 

j. 

Date/time configuration.  

 
Messages  will  be  parsed  and  changes  implemented  only  if  they  do  not  affect  the  operation  of 
the device in that moment, otherwise device  will  wait  until the change  has not impact over the 
normal operation. 
 
 

2.11. Firmware update

 

 
Device’s firmware can be remotely upgraded via GPRS. It is activated by sending a SMS. The 
device  automatically downloads the  new firmware as  long as  this does not interfere its normal 
functioning.  The  firmware  new  version  will  be  installed  when  the  device  be  connected  to  the 
charger and switched off.  
 
 

2.12. Security

 

 

The SMS communication is secured by the following mechanisms: 

a.  Whitelist of phone numbers. Only the defined numbers can call the device. 
b.  Password. 

 
 
 
 

 

Summary of Contents for IFALL

Page 1: ...www masermic com EN_MU_1502190 0 Fall detector with SMS GSM GPRS communications USER MANUAL EN_MU_15021900...

Page 2: ...__________________________________________ 6 3 USER INTERFACE SPECIFICATIONS _________________________________________ 7 4 GPS REPEATER FOR INDOOR LOCATION ____________________________________ 8 5 SMS...

Page 3: ...uring the night 2 FUNCTIONAL SPECIFICATION 2 1 User interface Device and components 1 Green LED indicates device status Starting seeking coverage blinking fast 0 25sg ON 0 25sg OFF ON non worn 0 5s ON...

Page 4: ...s closed after the 2 seconds Unplugging the device from the charger after being charged Turns on in standard mode The device turns OFF in three different ways Automatically when the battery is deplete...

Page 5: ...automatically picked up in hands free mode The user cannot start a call but can request it at the press of the panic button The incoming call decides when to end the communication and has always prior...

Page 6: ...munications d Password e Security perimeter f GPS position request g Activate deactivate fall detection h Activate deactivate the panic button i Restart the device j Date time configuration Messages w...

Page 7: ...onds blinking slowly 0 5s ON 2 5s OFF Optional Red LED flashes indicate GSM failure poor coverage or errors OFF MODE no light SPLASH 1sg orange green red vibration when turning ON OFF THE VIBRATION in...

Page 8: ...TION It is advisable to use a GPS repeater to make easier the indoor positioning The repeater on the picture consists of an antenna for satellite reception an antenna for GPS positioning the iFALL dev...

Page 9: ...t can be one of the following FALL alarm Automatic alarm generated by the fall detection algorithm See Note1 PANIC alarm Alarm generated by pressing the panic button See Note1 Battery low Low battery...

Page 10: ...osition it will be stored in the internal memory and when requested this last position will be sent Note 3 In these three cases the device could be turned off In that case these messages will be sent...

Page 11: ...device or use your internet browser to go to http play google com 2 Once there search for the App iFALLDET C and select it 3 When selected we will find a description of the App pictures and other info...

Page 12: ...nfiguration and use of iFALLDET C Start screen Once installed and open the user sees the following screens where the user will enter the telephone number from the iFALL device as well as the addresses...

Page 13: ...masermic com Then the user can enter the telephone number that will receive the messages following the same steps indicated for the iFALL number press the field Phone number 1 type it confirm and pres...

Page 14: ...14 www masermic com...

Page 15: ...15 www masermic com In the same way it is possible to configure a second destination number or alternatively leave it blank When left blank the scream will show 123456789...

Page 16: ...ss the field Send SMS messaging charts The information exchange between the device and the App is carried out through SMS commands which are totally transparent for the user The user can consult the c...

Page 17: ...hone number that will receive alarm and info messages 3 Phone 2 number Second telephone number that will receive alarm and info messages Usually these numbers are configured in the start screen The us...

Page 18: ...ined geographical limit 2 Perimeter center address sets both the address for the security perimeter center and the authorized radius for the iFALL carrier to go around before the perimeter alarm trigg...

Page 19: ...19 www masermic com To enable the security perimeter it is needed to tap on the option Security perimeter the application asks for confirmation in order to enable it...

Page 20: ...20 www masermic com Once enabled the user needs to determine a geographical centre and the radius in order to define the perimeter...

Page 21: ...21 www masermic com...

Page 22: ...ess and the radius can be modified later defining so a new security perimeter To do it the user only needs to enter new parameters again and press Accept If one of the parameters remains the same it i...

Page 23: ...of generating a panic alarm by the device To disable press on the Panic button field and confirm the action 3 Clear alarm cancels the existing alarm in force To disable press on the alarm cancellation...

Page 24: ...24 www masermic com...

Page 25: ...details 7 SPECIFICATIONS 7 1 HW Specifications 7 2 SW Specifications Parameter Unit Value Battery voltage lithium Capacity Autonomy GPS GSM GPRS Frequency of use VDC Ah hours Channels Hz 3 7 1 5 53 5...

Page 26: ...e Humidity IP IK 30 front 20 back 07 95 Vibration Intensity Mercalli Mod MAX IX Degree 7 4 Typical consumptions 8 ANNEX 8 1 Contact for technical support For technical enquiries you can contact our Af...

Page 27: ...does not cover product damage due to improper and use contrary to the instructions contained in the User Manual and Quick Reference Guide Nor product failures resulting from software installations mod...

Page 28: ...ed by the telecom operator The monitoring of end users corresponds exclusively to the end Customer being iFall a technological support tool that should be added to the safeguards used by the Customer...

Reviews: