023-001-058 REV C Fresh Air Supply System Instructions Page 5 of 41
If the unit still fails to operate return to Centurion Safety Products Ltd for repair.
All items should be transported in the packaging originally provided
Cleaning & Storage
The system should be cleaned by hand washing with a mild soap (non-detergent) then rinsing with
clean water and allowing to dry naturally. (Do not immerse the turbine unit in water or allow water
to enter the unit). Ensure that the complete system is fully dry before using. The belt bracket and
turbine unit should always be stored with protective caps in place.
Recommended storage temperature is 20°C, limits of storage conditions are -10 °C to +50 °C, R.H. < 60%.
DO NOT STORE IN DIRECT SUNLIGHT
. Items should be stored in the packing provided. When stored as detailed by
these instructions the system (excluding the full facemask) has a shelf life of 5 years. (See instructions supplied with the Full Face
Mask for details regarding its shelf life.)
All items should be transported in the packaging originally provided.
Applications and Uses
This system is designed to operate between -6°C and +50 °C
The turbine unit will provide a minimum of 120 ltrs/min of air to each port (which is the minimum requirement for this system).
This air can be provided to 2 users at a
MAXIMUM
distance of 40 metres each. The airflow can be increased by rotating the
control on the turbine in a clockwise direction. This should be adjusted to the preference of the user. An increase in setting may
be required if any of the following are relevant: Twin users, Long lengths of hose, Very high work rates.
When operating the system as unpowered, the
MAXIMUM
length of hose that should be used is
20 metres.
The system with class 2 hoses offers a Nominal protection factor of 2000 as defined in EN 138. It thus should not be used where
the level of contaminate in the atmosphere is greater than 2000 x Occupational Exposure Limit. It should be noted that EN 529
gives an assigned protection factor of 40 for the UK which may be used as an alternative protection factor limit. Refer to EN 529
for further guidance.
The Full facemask should be fitted, used and maintained in accordance with the instructions supplied with it.
WEEE (Refers to Mini Turbine ONLY)
THE MINI TURBINE SHOULD NOT BE DISPOSED OF IN GENERAL MUNICIPAL WASTE
1. The crossed-out wheeled bin symbol, with the solid bar, shown on this product, its packaging or instructions indicates that the
product has been manufactured after 13/8/05 and is subject to European Community directive 2002/96/EC, issued 27/1/03, on
correct handling of Waste Electronic and Electrical Equipment (WEEE).
2. WEEE cannot be disposed of as municipal waste and must be collected and disposed of separately. Appropriate public or
private waste collection systems defined by national and local regulations should be used.
3. The product may contain substances which could harm the environment or human health if disposed of incorrectly.
Standards
Both the unpowered and turbine powered fresh air systems are designed to EN 138 class 2. The current Mini-Turbine unit offers
mechanical/electrical protection to IP 54 as marked on the unit.
EC Type-examination by
:
BSI BRITISH STANDARD INSTITUTION, PO BOX 6221 Kitemark Court, Davy Avenue, Milton Keynes. MK1 9EP (Notified Body No
0086)
All Martindale Fresh Air Units are guaranteed free from any faults in materials or workmanship. Should any such faults
develop within 12 months of purchase then Centurion Safety Products Ltd will, at their discretion, repair or replace the unit
without charge.