DC Current

 

Range

Resolution

Accuracy

60A

0.01A

2.0% + 5

600A

0.1A

Overload protection: 660A DC or AC rms 

AC Current 

(True RMS)

Range

Resolution

Accuracy

(50 to 60Hz)

(60 to 500Hz)

60A

0.01A

2.0% + 5

3.0% + 5

600A

0.1A

Overload protection: 660A DC or AC rms

Resistance

Range

Resolution

Open circuit 

voltage

Accuracy

1000

:

0.1

:

3V dc

1.0% + 2

Overload protection: 600V DC or AC rms

Continuity

Open circuit voltage

Audible indication

3V dc

d

40

:

Overload protection: 600V DC or AC rms

Specification
CM79
TRMS AC/DC Clamp Meter

CM79 instruct rev1.indd   8

23/11/2015   11:00:59

GENERAL

Display: Liquid crystal display with maximum reading 6200

Sample rate: 3 times/sec

 Polarity: automatic, positive implied, ‘-‘ for negative polarity indication

Overrange: (OL) is displayed

Power: 2 x 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A)

Battery life (alkaline):  50 hours typical (without buzzer function or backlight) 

Low battery indication: 

 

symbol is displayed

Auto power off: after 30 minutes

Jaw opening capability: 25mm 

Dimensions: 210 x 62 x 36mm

Weight: 273g approx. Including batteries

Includes: carrying case, set of TL16 test leads, 2 x 1.5V AAA batteries, 

instructions

ENVIRONMENTAL

Temperature & Humidity:

(Operating): 0°C to 40°C <80% R.H., non-condensing

(Storage): -10°C to 60°C <70% R.H., batteries removed

Altitude: up to 2000m 

Pollution degree: 2

SAFETY

 

Conforms to: BS EN 61010-1, BS EN 61010-2-032, CAT III 600V

Class II, double insulation 

EMC

Conforms to BS EN 61326-1

Specification
CM79
TRMS AC/DC Clamp Meter

CM79 instruct rev1.indd   5

23/11/2015   11:00:58

SPECIFICATION FOR TL16 TEST LEADS

Maximum voltage: 1000V AC/DC

Maximum current: 10A continuous

Connector: 4mm banana plug with fixed shroud

Environmental

Temperature (Operating & Storage): 0°C to 40°C

Altitude: up to 2000m

Pollution degree 2

Safety

 

Conforms to BS EN 61010-031,  CAT IV 600V, CAT III 1000V, 10A (probe tip 

covers fitted)

 CAT II 1000V, 10A (probe tip covers 

removed)

Class II, double insulation

Specification
CM79
TRMS AC/DC Clamp Meter

CM79 instruct rev1.indd   4

23/11/2015   11:00:58

 17th Edition Testers

 Accessories

 

Calibration Equipment

 Continuity Testers

 Electricians’ Kits

 Environmental Products

 Full Calibration & Repair Service

 Fuse Finders

 Digital Clamp Meters

 Digital Multimeters

 Labels

 Microwave Leakage Detectors

 Motor Maintenance Equipment

 Multifunction Testers

 Non-trip Loop Testers

 Pat Testers & Accessories

 Phase Rotation Testers

 Proving Units

 Socket Testers

 Thermometers & Probes

 Test Leads

 Voltage Indicators

 Specialist Metrohm Testers (4 & 5kV)

 Specialist Drummond Testers

Check out what else you can get from Martindale:

Martindale Electric Company Limited

 

Metrohm House, Imperial Park, Imperial Way, 

Watford, Hertfordshire, WD24 4PP 

Metrohm House, Imperial Park, Imperial Way, 

Watford, Hertfordshire, WD24 4PP 

Tel: +44 (0)1923 441717  Fax: +44 (0)1923 446900

E-mail:[email protected]

 

Website: www.martindale-electric.co.uk

© 201

6

 Martindale Electric Company Ltd.

 

Registered in England No. 3387451. Rev1 LITCM79

CM79 instruct rev1.indd   1

23/11/2015   11:00:48

Summary of Contents for CM79

Page 1: ...tructions and product information are available at www martindale electric co uk 1 1 Meaning of Symbols and Markings Caution risk of danger refer to instructions Caution risk of electric shock Equipment protected by double or reinforced insulation Class II Application around and removal from hazardous live conductors is permitted CAT II Measurement Category II is applicable to test and measuring e...

Page 2: ...ngers behind the clamp safety protection barrier When making current measurements using the clamps disconnect the test leads from the clamp meter terminals Cautions Avoid severe mechanical shock or vibration and extreme temperature When using test leads avoid excessive stresses to the cable entry points at the probe and 4mm plug connector To avoid possible corrosion from leaking batteries remove t...

Page 3: ...function press for 2 seconds 8 3 11 Use of the TL16 Test Leads Before use always check the continuity of the test leads Where access to test points may require extended probe tips the probe tip caps may be removed by gently pulling them forward until they unclip from the probe body CAT III 1000V CAT IV 600V CAT II 1000V ONLY DO NOT USE ON CAT III or CAT IV installations 3 12 AC Current Measurement...

Page 4: ...ar to an approved Calibration Laboratory for recalibration and certification Martindale Electric is pleased to offer you this service Please contact our Service Department for details Email service martindale electric co uk Tel 01923 650660 4 4 Cleaning To reduce the risk of surface leakage this instrument must be kept in a clean condition Prior to cleaning ensure that the instrument is disconnect...

Page 5: ...erchantability or fitness for a particular purpose Martindale shall not be liable for any special indirect incidental or consequential damages or losses including loss of data arising from any cause or theory Since some jurisdictions do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or consequential damages the limitations and exclusions of this wa...

Page 6: ... 2 032 CAT III 600V Class II double insulation EMC Conforms to BS EN 61326 1 Specification CM79 TRMS AC DC Clamp Meter SPECIFICATION FOR TL16 TEST LEADS Maximum voltage 1000V AC DC Maximum current 10A continuous Connector 4mm banana plug with fixed shroud Environmental Temperature Operating Storage 0 C to 40 C Altitude up to 2000m Pollution degree 2 Safety Conforms to BS EN 61010 031 CAT IV 600V C...

Reviews: