Installation
8. Repeat steps 1 to 7 on the opposite side of the chute wall.
5.2.2
Installing the tensioner
Observe the respective instructions on installing the tensioner in the
respective operating manual of the tensioner used. (See Chapter
2.1.4).
5.2.3
Installing the primary cleaner
1. First remove the scraper blade from the mainframe as de-
scribed below:
• Open the safety clip (1, Fig.3) and pull it out for this
purpose.
• Then pull out the cleaner blade (2, Fig.3) from the spring
dowel sleeve (3, Fig.3).
2. Remove the two spring tensioners from the mounting plates.
NOTE
This is the best possible installation position recommended by
Martin Engineering for the MARTIN
®
XHD QC
™
#1 primary cleaner
to achieve optimum cleaning results. Should this not be possible
for structural reasons, the primary cleaner can, in consultation with
Martin Engineering, also be installed at an angle of 20° above or
below, but the installation radius must be adhered to in every
case.
Fig. 3: Installing the primary cleaner