34
RUSH™ Scanner 1 LED User Manual
Chan.
Value
Function
8
222-243 Counter-clockwise,
slow
→
fast
Random gobo
244-247 Fast
248-251 Medium
252-255 Slow
9
Prism
0-10 Open
11-138
Prism indexing (set angle on channel 10)
139-255
Prism rotation (set direction and speed on
channel 10)
10
Prism indexing / rotation
Prism indexing angle
0-255
Indexed position 0°
→
180°
Prism rotation direction and speed
0-2 No
rotation
3-126
Clockwise rotation, fast
→
slow
127-129 Stop
130-253
Counter-clockwise rotation, slow
→
fast
254-255 Stop
11
0-255
Focus, infinity
→
near
12
0-255 Pan
0
°
→
170
°
13
0-255
Pan (fine control)
14
0-255 Tilt
0
°
→
75
°
15
0-255
Tilt (fine control)
16
Functions / fixture settings
0-9
No function
10-14 Reset
all
15-19 Reset
color
20-24 Reset
gobo
25-29 Reset
focus
30-34 Reset
prism
35-39 Reset
pan/tilt
40-54
No function
55-59 Enable
calibration
60-79
No function
80-84
Pan/tilt speed = Normal
85-89
Pan/tilt speed = Fast (default setting)
90-94
Pan/tilt speed = Slow
95-99
Parameter shortcuts = On (default setting)
100-104
Parameter shortcuts = Off