background image

©

 19

95-19

96 Ma

rt

in P

rofe

ss

iona

l A/S

R o b o s c a n   P r o   1 2 2 0

o p e r a t o r ’ s   m a n u a l

P

art# 51

0061

Summary of Contents for Roboscan Pro 1220

Page 1: ...1995 1996 Martin Professional A S Roboscan Pro 1220 operator s manual Part 510061...

Page 2: ...sional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark Revisi...

Page 3: ...ng the Transport Fixture from the Pan tilt Assembly 11 section 3 OPERATING VIA A LIGHTING CONTROLLER Connecting the Data Link 12 Addressing the Pro 1220 13 Controlling 14 section 4 REMOTELY CONTROLLAB...

Page 4: ...Modules 23 Voltage and Frequency Setting 24 Lamp Replacement and Adjustment 25 Adjusting the Pan Tilt Stops 27 Adjusting the Pan Tilt Dampers 28 Regenerating Malfunctioning Lamps 29 section 7 MAINTENA...

Page 5: ...all speeds 176 degree pan in 0 028 degree steps 6 240 positions 85 degree tilt in 0 056 degree steps 1 504 positions 8 and 16 bit tracking available via DMX 512 Straight diagonal movements via vector...

Page 6: ...free position for an optional rotating prism M E C H A N I C A L C O N S T R U C T I O N Modular design for ease of servicing and flexibility Cover with snap lock and safety wire provides instant acce...

Page 7: ...1220 CMYR CPU A Section 2 0 219806 CPU B Section 2 0 219806 CPU Control Module 3 3 3 4 219810 EPROM A Section 2 6 2 7 2 8 219025 EPROM B Section 2 6 2 7 219026 Pro 1220 XR CPU A Section 2 0 219806 CPU...

Page 8: ...Osram and Pro 1220 MSR fix tures the single ended MSR 1200 from Philips Please follow the procedure below in order to install the lamp in a safe and proper way H M I 1 2 0 0 L A M P 1 Place the Pro 12...

Page 9: ...slide the whole main cover approxi mately 3 cm towards the mirror and then remove it upwards being careful not to damage the mirror while revealing the inside of the fixture 3 Locate the lamp holder a...

Page 10: ...a nd F r e q u e n c y S e t t i n g It is vital that the voltage and frequency setting on your Pro 1220 matches your local power supply If this is not the case you will have to rewire the fixture as...

Page 11: ...sides of the Pro 1220 2 Secure the bracket by first fitting the four metal washers and then the four lever handles that came with the Pro 1220 R e m ov i ng t h e T r a n s p o r t F i x tu r e fr o m...

Page 12: ...figure shows the proper connec tions in such a cable P N 309162 Please note that the and signal wires swap from the DMX output to the input on the Roboscan Pro 1220 2 If you are using one Roboscan Pro...

Page 13: ...220 requires for operation The following table shows the four different DMX protocols available Pro tocol 0 is only for use with a Martin controller 3 pin XLR female Pin 1 GND screen Pin 2 signal Pin...

Page 14: ...gn the fixture a DMX or Martin address confirm by pressing enter at dAdr or Adr 4 Use the up and down arrows to select the desired fixture address and confirm by pressing store Co n tr o l l in g Afte...

Page 15: ...te that both lamps are cold restrike types meaning that they have to be cold before re striking is possible For this reason you will have to wait 8 minutes after having turned off the lamp before you...

Page 16: ...rolling at the highest speed It is also possible to scroll the color wheel continuously forwards and backwards at different speeds Continuous color scroll also ensures that the Pro 1220 chooses the sh...

Page 17: ...ation of the prisms as with the rotating gobos F A N The Pro 1220 is efficiently cooled by means of axial fans The speed on the two large fans at the rear end of the fixture can be reduced from the co...

Page 18: ...t one of them The func tions provided are described in the following paragraphs and the function hierarchy is shown below d A d r D M X 5 1 2 A d d r e s s Use the arrow keys to select the fixture add...

Page 19: ...P E C S pe c i a l F u n c ti o n s Selecting this function presents you with a menu of special functions As in the main menu you can browse through the options and select the one displayed by pressin...

Page 20: ...link configuration page P A t I This function allows you to swap the pan and tilt channels in DMX Use the arrow keys to toggle between SUAP for swapped protocols and n SU for non swapped and press ent...

Page 21: ...is possible to reset this counter by keeping the arrow up key pressed for approx 5 seconds r L A R e s e ta b l e L a m p O n T i m e Selecting this option shows you the number of hours that the lamp...

Page 22: ...p power feedback circuit has failed The following information messages may appear on the display H o t This message appears if you attempt re strike the lamp within 8 minutes after having switched it...

Page 23: ...he Roboscan Pro 1220 has been designed with ease of servicing and maintenance in mind and is constructed in a totally modular fashion If there is a problem in any particular section or you want to put...

Page 24: ...fixture is dis connected from the mains supply P R O 1 2 2 0 C M Y R X R R P R 1 Locate on the front end of the Pro 1220 the Philips screw that secures the small cover over the voltage and frequency...

Page 25: ...e The adjustment procedure is as follows W A R N I N G Whilst adjusting the position of the lamp you will be exposed to extreme heat and intense light A minor risk of lamp explosion is also present an...

Page 26: ...ntil the Pro 1220 provides an almost uniform color projection across the entire image The color should only vary slightly and white edges on the image should be reduced to a minimum 9 Finally re assem...

Page 27: ...e that your are familiar with the service sequences provided by the control module on the front end of the Pro 1220 If not then please read section 5 THE PRO 1220 CONTROL MODULE First switch on the Pr...

Page 28: ...he edge of the mirror bracket D2 during these steps If it does then re adjust as described making the distance between C2 and C1 even smaller A d j u s t i n g t h e P a n T i l t D a m p e r s Re adj...

Page 29: ...sure that the fixture is dis connected from the mains supply 1 Locate the Philips screw that secures the small cover over the voltage and frequency termi nals on the front end 2 Locate the Brown wire...

Page 30: ...lters lenses and the reflector The colored surface on the filters is achieved by means of special coatings and even small scratches may be vis ible Use only a clean soft and lint free cloth like the o...

Page 31: ...econds Reset Lamp On 0 NOTE Only with LoFF oFF 0 NOTE Only with LoFF oFF 0 NOTE Only with LoFF oFF 0 49 50 177 178 199 200 247 248 251 252 255 Strobe Fan Speed Reset Lamp On No Function Strobe On Fast...

Page 32: ...3 0 10 20 30 40 50 60 70 80 90 97 98 105 106 113 114 121 122 129 130 137 138 145 146 153 154 161 162 208 209 255 Color 2 Pro 1220 CMYR RPR White CTC 5500 3400 Hot CTC 3500 5600 Cold Dark Orange Prima...

Page 33: ...Gobo 1 Indexed Gobo 2 Indexed Gobo 3 Indexed Gobo 4 Indexed Gobo 4 Continous rotation Gobo 3 Continous rotation Gobo 2 Continous rotation Gobo 1 Continous rotation 9 NOTE The Pro 1220 will re index th...

Page 34: ...m 3 Continous rotation Prism 2 Continous rotation Prism 1 Continous rotation 10 NOTE The Pro 1220 will re index the prism before moving the gobo to the programmed orientation 0 126 127 128 255 0 1 127...

Page 35: ...2 255 0 1 251 252 255 0 251 252 255 Speed Dimmer Cyan Magenta Yellow Iris Focus Tracking Speed Fast Slow Fast Speed Speed Color1 Color2 Gobo1 Prism Tracking Speed Fast Slow Blackout while moving Speed...

Page 36: ...20 CMYR ONLY St 1 All Open St 2 Magenta to adjust position Requires adjustment tool St 3 Cyan to adjust position Requires adjustment tool St 4 Yellow to adjust position Requires adjustment tool St 5 D...

Page 37: ...t 1 Open St 2 3 Facet Prism St 3 Frost St 4 5 Facet Prism SP 7 EFFECT WHEEL ADJUST Lamp On PRO 1220 XR ONLY St 1 Open St 2 CTC St 3 Frost St 4 3 Facet St 5 Open St 6 5 Facet SP 8 IRIS ADJUST Lamp On S...

Page 38: ...1 Pan Left Tilt Neutral St 2 Pan Right Tilt Neutral St 3 Pan Neutral Tilt Up St 4 Pan Neutral Tilt Down SP12 PRISM ADJUST Lamp On PRO 1220 RPR ONLY St 1 Open Position first St 2 Prism 4 SP13 LOCATING...

Page 39: ...ithout bracket 1107 mm 43 6 316 mm 12 4 462 mm 18 2 285 mm 11 2 Weight CMYR XR RPR models Weight CMYRST XRST RPRST models 53 kg 117 lb 51 Kg 112 lb 47 kg 103 lb 45 Kg 99 lb Fuse 20 AT 6 3 X 32 mm Powe...