9
O p e r a t i o n
s e c t i o n 3
O P E R A T I O N
S t a n d - A l o n e O p e r a t i o n
The RoboScan 812 may be operated without a controller in stand-alone mode. In this mode,
the fixture performs a random sequence that is triggered by the beat of the music or auto-
matically at a set speed. The DIP-switch must be set to the desired stand-alone mode before
applying power. Settings for the different modes are shown below.
1.
With the fixture powered off, set the DIP-switch (3) for the desired mode.
Pins not listed must be switched off.
2.
Apply power to the RoboScan 812 to run the sequence.
C o n t r o l l e r O p e r a t i o n
G e t t i n g S t a r t e d
The RoboScan 812 may be used with DMX-512 and Martin protocol controllers; it auto-
matically determines which protocol is in use. Protocol auto-detection can be reactivated if
necessary by switching on all ten DIP-switches and then resetting the address.
1.
Connect the RoboScan 812 to the controller and set the address.
2.
Switch on and configure the controller.
3.
Apply power to the RoboScan. After a short reset procedure it will
respond to the controller.
Stand-Alone Modes
Description
Pins Switched ON
Random sequence, wide pan/tilt, auto trigger
2, 10
Random sequence, wide pan/tilt, music trigger
1, 2, 10
Random sequence, narrow pan/tilt, auto trigger
2, 3, 10
Random sequence, narrow pan/tilt, music trigger
1, 2, 3, 10
Lamp ON
8, 10
Lamp OFF
7, 10
Adjustment sequence (for service use and lamp adjustment)
5, 10
L.E.D. chase auto-trig (for service use only)
4, 10
L.E.D. chase music-trig (for service use only)
1, 4, 10