1 5
S e r v i c e a n d M a i n t e n a n c e
5.
Remove the GRAY wire from the ballast terminal: insert a screwdriver in
the small hole under the terminal and release the spring with a clockwise
turn.
6.
Open the spring for the correct ballast terminal and insert the GRAY wire.
The terminals are marked on the side of the ballast.
7.
Reassemble the unit before connecting to AC power.
R e p l a c i n g t h e F u s e
The holder for the main fuse is built in to the mains input socket (4). If the fuse blows
repeatedly, the fixture requires servicing by a qualified technician.
Never replace the fuse
with one of a different rating!
1.
Unplug the mains cable from the input socket.
2.
Pry open the fuse holder and remove the fuse.
3.
Replace the fuse with one of the same type and rating. The fuse rating is
listed on serial number label on the end plate.
4.
Close the fuse holder and replace the mains cable.
812C.fm Page 15 Monday, September 3, 2001 4:23 PM