5
I n s t a l l a t i o n
s e c t i o n 2
I N S T A L L A T I O N
The RoboScan 812 is delivered fully adjusted from the factory; only a few setup steps are
necessary. Please follow them carefully to get the most out of your new equipment.
U n p a c k i n g
The packing material is carefully designed to protect the fixture during shipment - always
use it or a flight case to transport the fixture.
The RoboScan 812 comes complete with the following items:
•
150 W Martin Metal Halide discharge lamp
•
5 meters XLR-XLR cable
•
mains cable
•
mounting bracket and hardware
•
this user manual
I n s t a l l i n g a P l u g o n t h e P o w e r C o r d
W A R N I N G !
For protection from dangerous electric shock, the fixture
must be grounded (earthed). The AC supply shall be fitted
with a fuse or circuit breaker and ground-fault protection.
The RoboScan 812 is delivered without a plug on the power cord. Following the manufac-
turer’s instructions, install an approved 3-prong grounding-type plug that fits your supply.
Connect the wires to the pins as listed below. The table shows some possible pin identifica-
tion schemes; if the pins are not clearly identified, or if you have any doubts about proper
installation, consult a qualified electrician.
Wire
Pin
Marking
Screw color
brown
live
“L”
yellow or brass
blue
neutral
“N”
silver
yellow/green
ground
green
812C.fm Page 5 Monday, September 3, 2001 4:23 PM