16
Service and Maintenance
RoboColor III
2
On the ballast, move the BLACK wire to the correct voltage terminal. Use the
following table to select the correct voltage setting.
3
Re-assemble the unit.
F U S E S
Should the RoboColor III system cease to work it may be due to a blown fuse.
This section describes how to replace the fuses.
T o r ep l a ce th e pr i mar y fu s e
•
The primary fuse is located inside the IEC mains input socket at the rear of
the controller. Use a small screwdriver to pry open the fuse holder and
replace the fuse with one of the same size and rating. The fuse rating is also
printed on the serial number label.
50 Hz Model
60 Hz Model
Mains supply
Ballast tapping
Mains supply
Ballast tapping
210V - 235V
230V
200V - 215V
210V
235V - 245V
240V
215V - 225V
220V
245V - 255V
250V
225V - 235V
230V
Ballast
210V/60Hz
230V/60Hz
220V/60Hz
Ballast
230V/50Hz
250V/50Hz
240V/50Hz
50 Hz Version
60 Hz Version
IEC mains input
socket.
Mains fuse
6.3AT/250V (slow