4
Setting Up
RoboColor III
C he ck vo l t ag e set t i n g
Important!
The voltage setting of the heads must match your local AC mains
supply.
The RoboColor III head is supplied in a 50 Hz or 60 Hz version. It is not possible
to rewire from 50 Hz to 60 Hz, or vice versa.
•
The factory setting is printed on a label on the back of the head. Check the
setting against the table below and rewire if necessary, following the
instructions on page 15.
P R E P A R I N G T H E C O N T R O L L E R
I n st al l a mai n s pl ug
Warning!
For protection from dangerous electric shock, the fixture must
be grounded (earthed). The AC mains supply shall be have a
fuse or circuit breaker, and ground-fault protection.
The controller may be supplied without a plug on the mains cable. You will have
to fit a plug that conforms to your local mains outlet before you can connect the
unit to AC power. The double insulated mains cable contains three wires.
1
Connect the BROWN wire to the LIVE pin.
2
Connect the BLUE wire to the NEUTRAL pin.
3
Connect the YELLOW/GREEN wire to the EARTH pin.
50 Hz Model
60 Hz Model
Mains supply
Ballast tapping
Mains supply
Ballast tapping
210V - 235V
230V
200V - 215V
210V
235V - 245V
240V
215V - 225V
220V
245V - 255V
250V
225V - 235V
230V
Wire
Pin
Marking
Screw color (US)
brown
live
“L”
yellow or brass
blue
neutral
“N”
silver
yellow/green
ground green