Safety Information

 5

• Ensure that the P3 PowerPort 1500 is electrically connected to ground (earth).

• Connect the P3 PowerPort 1500 to AC mains power at 100-240 V (nominal), 50/60 Hz only.

• Use only a source of AC mains power that complies with local building and electrical codes and has both 

overload and ground-fault (earth-fault) protection. 

• Use only a power input cable that has 12 AWG or 4 mm² minimum conductor size and an outer cable 

diameter of 10 - 15 mm (0.4 - 0.6 in.). Power cable must be hard usage type (SJT or equivalent) and 
heat-resistant to 90° C (194° F) minimum. In the EU the cable must be HAR type.

• Use only the cables specified by Martin™ for the devices concerned to interconnect them. If the specified 

cables are not long enough for an intended cable run, consult Martin™ for assistance in finding or 
creating a safe alternative cable

• Before applying power to the installation, check that all power distribution equipment and cables are in 

perfect condition and rated for the current requirements of all connected devices.

• Isolate the installation from power immediately if the product, power cable or power plug are in any way 

damaged, defective or wet, or if they show signs of overheating.

• Do not expose the P3 PowerPort 1500 to rain or moisture. 

PROTECTION FROM BURNS AND FIRE

• Do not attempt to bypass fuses. Replace defective fuses with fuses of the same type and rating only.

• Provide free airflow and a minimum clearance of 100 mm (4 in.) around fans and air vents.

• Do not operate the P3 PowerPort 1500 if the ambient temperature (Ta) exceeds 45° C (113° F).

• Do not modify the P3 PowerPort 1500 in any way not described in this manual or install other than 

genuine Martin™ parts. Use only accessories approved by Martin™.

PROTECTION FROM INJURY

• When installing the P3 PowerPort 1500 above ground level, ensure that the primary installation hardware 

and supporting structure can hold at least 10 times the weight of all the devices they support.

• When suspending the P3 PowerPort 1500 from a rigging structure, use two rigging clamps that are 

approved by an official notified body for the weight they support and installed as described in this manual.

• In an overhead installation or where the P3 PowerPort 1500 may cause injury if it falls:

- block access below the work area and work from a stable platform whenever installing, servicing or 

moving the P3 PowerPort 1500,

- install as described in this manual a secondary attachment (such as a safety wire) that is approved in 

accordance with UL1573 Section 9.2 and EN 60598-2-17 Section 17.6.6 as a safety attachment for the 
weight it must secure if the primary attachment fails, and

- as soon as work is completed, check that all hardware and components are securely in place and that 

all installation and rigging hardware used is securely fastened.

Summary of Contents for P3 PowerPort 1500

Page 1: ...P3 PowerPort 1500 User Manual...

Page 2: ...ndirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document The Martin logo the Martin name and al...

Page 3: ...8 AC power 9 AC mains power input 9 DC power output 10 P3 video data 11 P3 video data input 11 P3 video data output 11 Using the product 12 Applying power 12 Status LEDs and control button 12 Service...

Page 4: ...service agents If you have any questions about how to operate the P3 PowerPort 1500 safely please contact your Martin supplier or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA...

Page 5: ...pt to bypass fuses Replace defective fuses with fuses of the same type and rating only Provide free airflow and a minimum clearance of 100 mm 4 in around fans and air vents Do not operate the P3 Power...

Page 6: ...ts Martin user documentation is supplied with products and available for download from the Martin website at http www martin com where you can also find the latest specifications firmware updates and...

Page 7: ...nel The rear panel of the P3 PowerPort 1500 is used for connections power on off and fuses Figure 1 Front panel overview Status LEDs Multi function control button AC mains power input connector Fan gr...

Page 8: ...support Check that the structure that will be used for suspension can bear at least 10 times the weight of all installed products clamps cables auxiliary equipment etc 2 Install the supplied clamp mo...

Page 9: ...werPort 1500 is connected to power via the Neutrik PowerCon input socket on the rear panel see Figure 2 on page 7 A suitable power cable with a PowerCon cable connector can be ordered from Martin Alte...

Page 10: ...er manuals carefully and respect the system layout guidelines and limits given in the manuals User manuals are supplied with products and available for download from www martin com The P3 PowerPort 15...

Page 11: ...t To send P3 video data to the P3 PowerPort 1500 connect an Ethernet cable carrying the P3 video data output from a Martin P3 system controller to one of the P3 PowerPort 1500 s RJ 45 P3 data input th...

Page 12: ...us information given by the LEDs on the P3 PowerPort 1500 front panel is printed on the panel For each of the four outputs The LED in the Data column lights when data is being transmitted at that outp...

Page 13: ...utton If any of the outputs of the P3 PowerPort 1500 have been disabled because of an overload or short circuit pressing the control button will re enable the output s at the same time as it applies a...

Page 14: ...one of the outputs or the entire device stops working a fuse may have blown Fuses in group 1 protect outputs 1 and 2 Fuses in group 2 protect outputs 3 and 4 To replace a fuse 1 Disconnect the P3 Powe...

Page 15: ...air filters and fan grill covers 5 Wipe the outside of the product with a cloth lightly moistened in a mild detergent solution Do not splash with water Do not use any product that contains abrasives o...

Page 16: ...t Reset circuit breaker by sending command from P3 controller or pressing multi function button on front panel If circuit breaker trips again Output may be overloaded See user manuals of all connected...

Page 17: ...s extendable with Ethernet switch System Integration VC Dot Series via VC Feeder VC Grid Series See www martin com for latest information Construction Color Matt black Housing Steel and aluminum Prote...

Page 18: ...r data output extension cables Hybrid 4 pin XLR extension cable 1 m 3 3 ft P N 11821016 Hybrid 4 pin XLR extension cable 2 5 m 8 2 ft P N 11821017 Hybrid 4 pin XLR extension cable 5 m 16 4 ft P N 1182...

Page 19: ...Martin products FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this devi...

Page 20: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: