background image

P3 video data

 11

P3 video data

The P3 PowerPort 1500™ is designed to relay video data from a Martin P3™ system controller to a 
Martin™ LED-based video display system.

See Figure 2 on page 7. The P3 PowerPort 1500 has two RJ-45 Ethernet sockets on the rear panel. Either 
socket can be used for P3 video data input or throughput. The P3 PowerPort 1500 has four 4-pin locking 
XLR sockets for combined DC power and P3 video data output to Martin™ video display devices.

Handling RDM and/or DMX data

The P3 PowerPort 1500 is intended for use with video data and does not support DMX or RDM (Remote 
Device Management), although it will relay DMX-controlled video data from a P3 system controller that is 
connected to a DMX control source. To connect a DMX or RDM controller to Martin™ video display devices, 
you must connect directly to devices using cables available from Martin™. See device user manuals for 
details.

P3 video data input

The P3 PowerPort 1500’s Ethernet video sockets on the rear cover are designed to accept Neutrik RJ-45 
Ethercon connectors in protective shells as installed on most Martin™ P3 Ethernet video data cables, but 
standard RJ-45 connectors can be used.

Connecting video data input

To send P3 video data to the P3 PowerPort 1500, connect an Ethernet cable carrying the P3 video data 
output from a Martin P3™ system controller to one of the P3 PowerPort 1500’s RJ-45 P3 data 
input/throughput Ethernet sockets.

If required, connect an Ethernet cable from the P3 PowerPort 1500’s unused RJ-45 data in/throughput 
socket to continue the P3 video data link and relay data to another P3-compatible device.

P3 video data output

Warning! Before you connect devices to the P3 PowerPort 1500’s power + data outputs, read all the 
devices’ user manuals carefully and respect the system layout guidelines and limits given in the 
manuals. User manuals are supplied with products and available for download from 
www.martin.com.

The P3 PowerPort 1500™ relays P3 video data to Martin™ video display devices over the hybrid DC power 
+ video data cable available in various lengths from Martin™.

Connecting video data output

To link the P3 PowerPort 1500 to devices, connect Martin™ hybrid cables with 4-pin male locking XLR 
connectors to the P3 PowerPort 1500’s four power + data output sockets on the rear panel (see Figure 2 on 
page 7). Use only the cables supplied by Martin™ for this purpose. Hybrid power + data extension cables 
with 4-pin male XLR to 4-pin female XLR connectors are available from Martin™ (see ”Accessories” on 
page 18). Do not exceed the maximum lengths for cable runs specified in user manuals.

Summary of Contents for P3 PowerPort 1500

Page 1: ...P3 PowerPort 1500 User Manual...

Page 2: ...ndirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document The Martin logo the Martin name and al...

Page 3: ...8 AC power 9 AC mains power input 9 DC power output 10 P3 video data 11 P3 video data input 11 P3 video data output 11 Using the product 12 Applying power 12 Status LEDs and control button 12 Service...

Page 4: ...service agents If you have any questions about how to operate the P3 PowerPort 1500 safely please contact your Martin supplier or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA...

Page 5: ...pt to bypass fuses Replace defective fuses with fuses of the same type and rating only Provide free airflow and a minimum clearance of 100 mm 4 in around fans and air vents Do not operate the P3 Power...

Page 6: ...ts Martin user documentation is supplied with products and available for download from the Martin website at http www martin com where you can also find the latest specifications firmware updates and...

Page 7: ...nel The rear panel of the P3 PowerPort 1500 is used for connections power on off and fuses Figure 1 Front panel overview Status LEDs Multi function control button AC mains power input connector Fan gr...

Page 8: ...support Check that the structure that will be used for suspension can bear at least 10 times the weight of all installed products clamps cables auxiliary equipment etc 2 Install the supplied clamp mo...

Page 9: ...werPort 1500 is connected to power via the Neutrik PowerCon input socket on the rear panel see Figure 2 on page 7 A suitable power cable with a PowerCon cable connector can be ordered from Martin Alte...

Page 10: ...er manuals carefully and respect the system layout guidelines and limits given in the manuals User manuals are supplied with products and available for download from www martin com The P3 PowerPort 15...

Page 11: ...t To send P3 video data to the P3 PowerPort 1500 connect an Ethernet cable carrying the P3 video data output from a Martin P3 system controller to one of the P3 PowerPort 1500 s RJ 45 P3 data input th...

Page 12: ...us information given by the LEDs on the P3 PowerPort 1500 front panel is printed on the panel For each of the four outputs The LED in the Data column lights when data is being transmitted at that outp...

Page 13: ...utton If any of the outputs of the P3 PowerPort 1500 have been disabled because of an overload or short circuit pressing the control button will re enable the output s at the same time as it applies a...

Page 14: ...one of the outputs or the entire device stops working a fuse may have blown Fuses in group 1 protect outputs 1 and 2 Fuses in group 2 protect outputs 3 and 4 To replace a fuse 1 Disconnect the P3 Powe...

Page 15: ...air filters and fan grill covers 5 Wipe the outside of the product with a cloth lightly moistened in a mild detergent solution Do not splash with water Do not use any product that contains abrasives o...

Page 16: ...t Reset circuit breaker by sending command from P3 controller or pressing multi function button on front panel If circuit breaker trips again Output may be overloaded See user manuals of all connected...

Page 17: ...s extendable with Ethernet switch System Integration VC Dot Series via VC Feeder VC Grid Series See www martin com for latest information Construction Color Matt black Housing Steel and aluminum Prote...

Page 18: ...r data output extension cables Hybrid 4 pin XLR extension cable 1 m 3 3 ft P N 11821016 Hybrid 4 pin XLR extension cable 2 5 m 8 2 ft P N 11821017 Hybrid 4 pin XLR extension cable 5 m 16 4 ft P N 1182...

Page 19: ...Martin products FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this devi...

Page 20: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: