Basic service
Basic service
Before servicing the JEM Compact Hazer Pro, read and observe all the
precautions listed in “Safety information” on page 4. Any service not described in
this section must be carried out by a Martin service technician.
To find your local Martin service center visit
www.martin.com
C l e a n i n g
Excessive dust, haze fluid, and dirt build-up will degrade performance and cause
overheating and damage to the machine that is not covered by the product
warranty. To maintain adequate cooling, dust must be cleaned from the outer
casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The haze output nozzle remains hot for a period after use.
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
Clean haze fluid residues from the haze output of the machine using a
damp cloth.
Clean the outer casing with a damp cloth only.
M a r t i n P r o - C l e a n a n d S t o r a g e F l u i d
Martin Pro-Clean & Storage Fluid
is specially designed for optimizing
performance while providing longevity of any effect machine. Martin Pro-Clean &
Storage fluid is the ultimate cleaning solution for Martin atmospheric effect heat
exchangers. This advanced preventative maintenance fluid has been utilized by
Martin service technicians for years of both cleaning and storing effect machines.
Utilizing Martin Pro-Clean & Storage Fluid
on a regular basis reduces clogging
and further extends the life of your Martin atmospheric effect machines. By using
the highest grade chemicals available while remaining eco-friendly, Martin fluids
are both effective and safe.
I n s t r u c t i o n s f o r u s e
Use fluid directly from container,
do not dilute
. Remove cap and safety seal; if
inner safety seal has been tampered with, return product to point of purchase.
Disconnect effect machine from power source before filling reservoir. When
possible, remove reservoir from machine and carefully fill reservoir to desired
level, taking care not to overfill or spill. Wipe up any spilled fluid with a damp
cloth. Replace cap on container and store upright in a secure location.
C l e a n i n g a n d P r e v e n t a t i v e M a i n t e n a n c e P r o c e d u r e :
Use Martin Pro Clean and Storage Fluid after every 200 hours of operation or
monthly depending on usage and duty cycle. In a well-ventilated area temporarily
connect Martin Pro Clean and Storage Fluid to the effect machine being serviced
or fill the machines provided fluid reservoir. Allow the machine to fully heat.
When machine is ready activate the machine to run continuously for 30-45
minutes; use a timer function if available.
S t o r a g e P r o c e d u r e :
Perform the above cleaning and preventative maintenance procedure. After
procedure is completed simply run the machine until all fluid has been visibly
purged from the fluid inlet tubing to prevent leaks and seepage.