52
Exterior Projection 500 User Manual
Troubleshooting
This section describes some possible problems that you may experience and provides some
suggestions for easy troubleshooting:
Symptom
Potential cause
Remedies
No light from
fixture.
Power supply issue such
as faulty connector or
damaged cable.
Ensure that the mains supply is connected
and supplying power to the fixture. Check all
power connections and cables.
Fixture does not
respond correctly
to DMX control.
Incorrect DMX setup.
Fault in the DMX network
due to connector or cable
damage or potential
interference from proximity
to a high voltage
installation.
Internal fault.
Ensure that fixture’s DMX address matches
address set on DMX control device.
Check that fixture’s status LED shows that it is
receiving DMX. If not, check all DMX cables
and connections.
Ensure that DMX link is terminated.
Check that all components on DMX link use
standard DMX polarity.
Attempt to control the fixture with another
DMX control device.
Move or shield the DMX link if it is close to an
unshielded high-voltage installation.
Contact your Martin authorized distributor or
Martin Global Service for assistance.
Condensation
visible on inside of
front glass.
Humidity inside fixture.
Condensation inside the fixture is normal in
some atmospheric conditions. The fixture will
gradually expel humidity via its Gore-Tex
pressure relief valve as it cycles on and off.
If required, you can remove excessive
humidity by following the directions given in
‘Removing and reinstalling the top cover’
starting on page 32.
Summary of Contents for Exterior Projection 500
Page 1: ...Exterior Projection 500 User Manual...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...