2. Connect the conductors in the power cable to the distribution circuit as follows:
a) Connect the green wire (US models) or yellow/green wire (EU models) to ground (earth).
b) Connect the white wire (US models) or blue wire (EU models) to neutral.
c) Connect the black wire (US models) or brown wire (EU models) to live (one phase of a
three-phase system).
3. Check that all installation work is completed and carry out appropriate tests and safety checks
before applying power.
Installing a temporary power plug
It is possible to install a power plug on the power cable for temporary use (such as setting up a
fixture before installation) only. If you choose to do this, install a grounding type (earthed) plug with
integral cable grip that is rated minimum 277 V, 6 A. Follow the plug manufacturer’s instructions
and connect the wires in the power cable as shown in the table below:
Live or L
Neutral or N
Earth, Ground or
US system
Black White
Green
EU system
Brown
Blue
Yellow/green
Power plug connections