Exterior Projection 500 User Manual
51
Warning and error messages
The Exterior Projection 500 monitors its own operation and is capable of self-diagnosis. If an
operating parameter such as ambient temperature is exceeded or if an error occurs, the fixture
displays a warning or error message in its onboard LCD display.
If the fixture displays a warning or error message, it can also send a four-character code to an
RDM controller. Depending on which controller you are using, these codes may be displayed
automatically or you may need to send a command to get the codes from the fixture.
The following table explains the warning and error message codes in RDM:
Message in display
RDM code Notes
Err Gobo Wheel
9017
Gobo wheel error
Err Gobo ind/rot
9018
Gobo indexing/rotation error
Err 3_Facet_Prism
9028
3-facet prism error
Err Line Prism
9062
Linear prism error
Err Prism Rot
9029
Prism rotation error
PSU Fan
9059
Internal PSU fan error
Err Color wheel
9015
Color wheel error
Err Animation
901B
Animation system error
Err Focus
901D
Focus error
Environment temp out of
range
8003
Ambient temperature exceeded
Summary of Contents for Exterior Projection 500