is factory wired for 277 volt supply then see “Adjusting power on 277 volt
models” on page 73.
Warning!
Disconnect the fixture from AC power before removing any
cover.
1. Make sure the Exterior 600 is isolated from AC power and has cooled
for at least 20 minutes.
2. Remove the 10 Allen screws from the
rear cover plate. Carefully remove the
plate and seal.
3. Find the row in the above table with the
local AC frequency and voltage. Follow
the row to the right to find the correct
transformer and ballast tappings. For
example, with a local AC supply of 230V,
50 Hz, the correct transformer tapping is terminal 6 and the correct
ballast tapping is terminal 10.
4. To tap the transformer, move the 2 BROWN wires to the correct
terminal. Terminals are identified on the transformer in front of the
connection tabs.
5. To tap the ballast, move the single BROWN wire to the correct terminal.
6. Check the condition of the cover plate seal. Replace with a new one
(P/N 20600020) if the seal is torn, cracked or brittle.
7. Insert the Allen screws through all holes in the cover and the seal. Place
the cover firmly against the body.
Local AC Power
Transformer
Ballast
Frequency
Voltage
Setting Terminal
Setting
Terminal
50 Hz
200-210 V
210 V
4
200 V / 50 Hz
7
210-220 V
210 V
4
230 V / 50 Hz
10
220-235 V
230 V
6
230 V / 50 Hz
10
235-240 V
230 V
6
245 V / 50 Hz
12
240-260 V
250 V
8
245 V / 50 Hz
12
60 HZ
200-217 V
210 V
4
208 V / 60 Hz
4
217-240 V
230 V
6
227 V / 60 Hz
7
Ballast
Trans-
former