AC power
13
AC power
Power configuration
This section describes connection to AC power. Your Exterior 600 is factory-
wired to one of the following settings:
• 230 V, 50 Hz
• 245 V, 50 Hz
• 208 V, 60 Hz
• 277 V, 60 Hz
Operating at the incorrect power setting can result in poor light output,
greatly reduced lamp life, overheating and damage to the fixture. The
factory settings are printed on the serial number label. If your local AC
voltage or frequency differ from the settings for your model, then see
“Changing the power settings” on page 71.
Connection to power
Warning!
For protection from dangerous electric shock, the fixture must
be grounded (earthed). The AC power system must be fitted
with current overload and ground-fault (earth fault) protection.
Important! Do not connect the Exterior 600 to an electrical dimmer system.
Doing so can damage the electronics.
The Exterior 600 is supplied with a 3 meter (9.8 ft.) length of 3-conductor
0.75 mm
2
(~18 AWG) electrical cable, neoprene jacket type, for connection
to AC power. The cable enters the fixture through an IP68 cable gland that
fits 5.5-10 mm (1/4-2/5 in.) diameter cables.
Note:
If the power cable jacket is open at any point (for example at a
connection or if damaged), and if the opening is exposed to
water, moisture can be drawn up the inside of the cables when
temperature fluctuation during operation causes expansion and
contraction. When installing the product outdoors, always
ensure that the fixture is protected from water entry via the
power cable by:
Summary of Contents for Exterior 600
Page 1: ...Exterior 600 user manual m a r t i nar chi te ctu ra l ...
Page 4: ...4 ...
Page 30: ...30 General operation ...
Page 56: ...56 DMX protocol ...