30
M4082E
ZA
2022-07 CSP1 S
Figure 13: Measure Cleaner Angle
4.7 Tensioning cleaner
1. Measure angle of cleaner.
2. Determine tension required according to tensioning chart.
3. Tighten tensioners. Install and tighten jam nut against tensioning nut
on each tensioner.
4. Make sure outer two elements on each side are away from belt.
*Lower rope should have 10% to 15% less force than upper rope.
CSP Size
Belt Width
Upper Rope
Force Required
Lower Rope
Force Required*
mm
(in.)
Small
500
18
1.00 kN
0.85 kN
501
–650
24
1.20 kN
1.00 kN
651
–800
30
1.40 kN
1.20 kN
801
–900
36
1.50 kN
1.30 kN
901
–1000
42
1.60 kN
1.40 kN
Installation Checklist
– Please make sure
Pre-Cleaner blade is proper distance from belt surface on both sides of head pulley.
Pre-Cleaner blade tip does not lie in path of material flow.
Blade is centered on belt.