3E EVAPORATOR OPERATION
Persons working in and around the cellar cooler must ensure that sources of ignition are not brought into the
area.Loading and unloading of product should be carried in a way to ensure that damage to the refrigeration
containing components cannot occur. Smoking and naked flames should be prohibited within the cellar and the area
around the condensing (outdoor) unit.
In the rare case of a leak occurring. Immediately contact an F Gas approved refrigeration technician. Do not open the
door to the cellar. Keeping the door closed will help to maintain the storage temperature of the product and prevent a
potentially flammable mixture leaking into to the environment outside the cellar. If product has to be removed from the
cellar to be moved to another refrigerated storage facility, please undertake the following procedure:
1. Keep unauthorised personnel away
2. Ensure no smoking, no naked flame and no other potential sources of ignition are present
3. Make sure there is adequate ventilation
4. Open the door to the cellar
5. Wait 30 seconds before entering the cellar
6. Remove product from the cellar as quickly as possible
7. Close the cellar and do not re-enter until the refrigeration technician says that it is safe to do so
If the leak is identified as occurring outside the cellar, but inside a building or enclosure, ensure adequate ventilation.
No source of ignition shall be energised or brought into the area until the environment is proven to be safe.
TEMPERATURE CONTROL (Do not set the controller below 4⁰C.)
The SET temperature is factory set at 12⁰C.
The digital display normally displays the return air temperature.
To change the SET temperature
, press and hold down the SET
button. If no alarms active, the ‘St1’ label appears and the current
value
is shown on the screen and will flash.
To change the Setpoint value
, press ▲ and ▼ keys within 60
seconds.
The display will revert to the return air temperature after 60 seconds.
The fitted de-ice thermostat will activate a de-ice cycle when there is
a
build up of ice on the evaporator coil.
Cellarators will only heat a room if the electric heater option is fitted.
Displaying inputs on screen display
Press ▼ to display the current input. There are 6 inputs to select
from
to display onto the screen. These are as follows:
b1: probe 1;
b2: probe 2;
di1: digital input 1;
di2; digital input 2;
St1: set point 1;
St2: set point 2;
Press ▲ and ▼ to select the input to be displayed. Press
set
for 3 seconds to confirm your choice.
To display the live temperature in the room you need to select b1: probe
WARNING
The following actions could damage your system:
1.
Switching the unit OFF and ON quickly
2.
Setting the unit to HEAT and then back to COOL quickly
Summary of Contents for A2LCELLARMATCH
Page 1: ...55908059 01 A2LCELLARMATCH TECHNICAL MANUAL ...
Page 12: ...55908059 01 12 2G CONDENSING UNIT WIRING DIAGRAMS ...
Page 14: ...55908059 01 14 ...
Page 22: ...55908059 01 22 2K COMPONENT IDENTIFICATION SMC ...
Page 31: ...55908059 01 31 3H EVAPORATOR WIRING DIAGRAM 3I REFRIGERANT SYSTEM SCHEMATIC DIAGRAM ...