 Installation

Instructions

Installation Instructions

Preparation

NOTE:
All the illustrations in the manual are for explanation purpose only.  Your machine may be slightly different. 
The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote 
controller. This manual does not include Remote Controller Operations, see the <<Remote Controller 
Instruction>> packed with the unit for details. 

Design Notice

In order to ensure the optimal performance of our products, the design specifications of the unit 
and remote control are subject to change without prior notice. 

rear

front

control panel
remote signal receptor

handle

(both sides)

horizontal louver control 

lever(adjust manually)

vertical louver control 
lever(adjust manually)

panel

Caster

bottom tray 

drain outlet

          air filter

upper air intake

air outlet

lower air intake

drain outlet 

NOTE: PHA can not be
adjusted.

NOTE: PHA can not be
adjusted.

recovery occurs. The recovery equipment shall be in good working order with a set of instructions 
concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. 
In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall 
be complete with leak-free disconnect couplings and in good condition. Before using the recovery 
machine, check that it is in satisfactory working order, has been properly maintained and that any 
associated electrical components are sealed to prevent ignition in the event of a refrigerant release. 
Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier 
in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants 
in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, 
ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant 
does not remain within the lubricant. The evacuation process shall be carried out prior to returning the 
compressor to the suppliers. Only electric heating to the compressor body shall be employed to 
accelerate this process. When oil is drained from a system, it shall be carried out safely. 

Summary of Contents for PS-101B

Page 1: ...www marsdelivers com Owner s Manual Installation Manual Portable Air Conditioner PS 81B PS 101B...

Page 2: ...recautions Air Filter Cleaning Troubleshooting Tips Unit Cleaning Store the unit when not in use Preparation Design Notice Energy Rating Information Ambient Temperature Range For Unit Operating Exhaus...

Page 3: ...the nameplate located on unit have a qualified electrician install the proper receptacle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibra...

Page 4: ...he appliance Children must be supervised around the unit at all times be applicable for other countries except the European Countries If the supply power cord is damaged it must be replaced by the man...

Page 5: ...ntact a qualified person to carry out repairs If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired Hold the plug by th...

Page 6: ...ce of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Please follow the instructions carefully to handle install clear a...

Page 7: ...system 2 Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed 3 General work are...

Page 8: ...ly into the atmosphere 8 Checks to the refrigeration equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufac...

Page 9: ...the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from t...

Page 10: ...actice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant...

Page 11: ...ructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales shall be available and in good workin...

Page 12: ...cedure not to the portable air conditioners themselves The energy rating and noise information for this unit is based on the standard installation using and un extended exhaust duct without window sli...

Page 13: ...etermine the square footage of the room you want to cool by multiplying the room length by its width You also need to know the air conditioner s BTU British Thermal Unit rating which indicates the amo...

Page 14: ...ose 1 pc 1 pc Window Slider Adaptor Power Cord Buckle O N O F F T E M P S H O R T C U T T IM E R O N T IM E R O F F M O D E FA N S LE E P S W IN G LE D 1 set 1 pc Window Slider B Remote Controller and...

Page 15: ...sliders once they are adjusted to the Proper length Window slider A Window slider B Bolt Window slider A Window slider B Window slider C Bolts Step Two Install the Exhaust hose assembly to the unit Pu...

Page 16: ...sash and frame as shown Foam seal B Adhesive type shorter Foam seal A Adhesive type Or Or Window slider A Window slider B if required Foam seal C Non adhesive type 3 Cut the non adhesive foam seal C s...

Page 17: ...he actual shape shall prevail NOTE Cover the hole using the adaptor cap when not in use max 120cm or 47 inch min 30cm or 12 inch Expansion anchor position Adaptor cap Wall Exhaust Adaptor B Or 5 Inser...

Page 18: ...set temperature while on COOL HEAT or AUTO MODE While on DRY and FAN modes it shows the room temperature Shows Error codes E0 EEPROM error E1 Room temperature sensor error E2 Evaporator temperature s...

Page 19: ...ows AP to indicate you can set wireless connection If connection router is successful within 8 minutes the unit will exit wireless connection mode automatically and the wireless indicator illuminates...

Page 20: ...end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Continuous drain hose Remo...

Page 21: ...he unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Drain the unit s water collection tray according to the instructions in the following section Run the ap...

Page 22: ...cian to inspect the unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Double check the cooling area Turn off the unit disconnect the hose check for b...

Page 23: ...warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagno...

Page 24: ...GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEO...

Reviews: