HB36 - How to Install Clean View Kit (Cvck)
For HB36/HB42/HB47
CAUTION: When using CVCK DO NOT INSTALL a Louver assembly.
1. Install optional fan kit (see Fan Instruction).
2. Fold two standoffs up into position and mount with supplied screws. (FIG 1)
3. Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2)
4. Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
5. Using four supplied #6 screws, fasten CVCK kit to the inside frame of unit.
6. Kit is supplied with 2 valve extension knobs. Align the notches and slide the extensions onto valve knobs.
7. DO NOT brick or tile beyond the inside area of the CVCK kit to allow for removal of door.
8.
Install optional pull screen system: First slide curtain onto rods and slide round end of rod into side post (REF A). Using 1/2” DT
screws, mount the flattened end of rod to bottom side of rod hanger bracket (REF B). Repeat this step for opposite side
.
NOTE:
ADDITIONAL ACCESS FOR GASLINE INSTALLATION AND FAN ELECTRICAL INSTALLATION! When CVCK is
installed in framing, remove 2 screws from the right and left side of the bottom panel (REF C). Once screws are removed,
bottom panel can be rotated forward for access to gas valve and fan system.
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace)
60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Top of 90 degree bend in Minimum
Enclosure of 42 to 43 inches
3 1/2 inches/89 mm / All Vent Systems
Top of 90 degree bend in
Enclosure over 43 inches
2 1/2 inches/64 mm / All Vent Systems
Top of Horizontal Pipe
1 1/2 inches/38 mm / All Vent Systems
Side & Bottom of Horizontal Pipe
1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk
Direct Temp Systems
WARNING:
Failure to position
the parts in accordance with these
diagrams or failure to use only parts
specifically approved with this
appliance may result in property
damage or personal injury.
NOTE:
When using the Clean View
Kit (CVCK) and installing optional
electrical components (i.e. Remote
Controls, variable speed control, and
or fan modules) locate them in the
Clean View access area, unless other
shielding devices like our IPI
Component box is used.
(NOTE -Floor) if installing the
appliance directly on
carpeting or other combustible
materials other than wood
flooring, the appliance shall be
installed on a metal or wood
panel, the full width and depth
of the appliance. Carpet may
extend 1 inch above the floor
of appliance.
For units with CVCK (Clean
View Circulating Kit) see
framing with CVCK to
establish floor heights
11