5
2
Installation of System
Prior to installing
Do not install equipment to places where
• the spot will be submerged by splashes of seawater and/or rainfall.
• the spot will become difficult in works of inspection, maintenance, piping or else.
• the spot will suffer high temperature under direct sunbeams or close to high temperature pipings.
• the spot will be affected by intensive vibration close to engine or else.
Outline and installing dimensions of each unit are shown on Drawings. Receiving Cylinder must be
installed especially just as shown on Drawings.
Installation of Helm Pump (HRP-18-
Ⅱ
/HRP-23)
1. Install Helm Pump on the place in bridge or so
where its height is easy to steer. Select steady
position not rickety when steering wheel is
turned.
2. Installing angle can be chosen widely from ver-
tical to nearby horizontal.
15
°
Fixing bolts
Adapters
Elbow fittings
Fixing stand
Fitting bolts
Adapters
Elbow fittings
In case of Foot mount type
In case of Dashboard mount type
1. Foot mount type or Dashboard mount type
can be installed depending on installing
place. By using template appended at the
end of this manual, drill holes for fixing bolts
and piping, and fix the unit tightly with bolts
and nuts.
Installing Position and Angle of Helm Pump
For installation of Foot mount type, use M8 x 25
bolts. For installation of Dashboard mount type,
use M8 x 45 bolts.
2. Peel off protection plugs of Helm Pump and fit
adapters beforehand, then insert them to
elbow fittings.
3. Once installed Helm Pump, mount wheel to
Helm Pump and fix it with nuts.
Caution
Be sure to install semicircular key along key fit-
ting groove when installing wheel.
Caution
Apply caulking materials to fitting surface, if
necessary, to avoid water penetration into
inside of boat.
Caution
Don't install it at the place where steering is
disturbed. When installing it at such a place
where front visibility is impeded or steering
is disturbed, it may cause damage.
Summary of Contents for CL-10SET
Page 1: ...Hydraulic Steering System MSS Installation Manual MB 030200 1E...
Page 21: ...20 50 140 4 9 124 PCD146 Template of Helm Pump HRP 18 2F D HRP 23F D...
Page 22: ...21 102 120 102 120 4 9 Template of Helm Pump HRP 30 2F HRP 38F...
Page 23: ...22 160 188 60 88 4 11 Helm Pump HRP 30 2D HRP 38D...
Page 24: ...MAROL CO LTD 2 1 34 Ohashi cyo Nagata ku Kobe Japan TEL 81 78 611 2159 FAX 81 78 641 2908...