Marley K151FC Installation, Operation & Maintenance Instructions Manual Download Page 5

lIMITed WArrAnTY

All  products  manufactured  by  Marley  Engineered  Products  are  warranted  against  defects  in  workmanship  and  materials  for  one  year  from  date  of  installation,  except 
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment  improperly  installed  or  wired  or 
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to
Marley Engineered Products Service Center. Within the limitations  of this warranty, inoperative units should be returned to the nearest Marley authorized service center
or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such
repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS
AGREEMENT.  MARLEY  ENGINEERED  PRODUCTS SHALL  NOT  BE  LIABLE  FOR  CONSEqUENTIAL  DAMAGES  ARISING  WITH  RESPECT  TO  THE 
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.

HoW To obTAIn WArrAnTY SerVICe And 
WArrAnTY PArTS PluS GenerAl InForMATIon

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

note:

When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

470 beauty Spot rd. east
bennettsville, SC  29512 uSA

Summary of Contents for K151FC

Page 1: ...s heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is intended for comfort heating applications and not intended for use in special environments Do not use in damp or wet locations such as marine or greenhouse or in areas where corrosive or chemical agents are present 12 When installing see I...

Page 2: ...ng 2 All wiring procedures and connections must be in accordance with the National and Local Codes having jurisdiction and the heater must be grounded 3 Power supply must enter back box through the knockouts See also TOP marking on the back box for proper orientation 4 Verify the power supply voltage coming to heater matches the ratings as shown on the heater nameplate CAuTIon ENERGIzING HEATER AT...

Page 3: ...Then remove the knockout from the top of the box and proceed to step c b Remove the knockout on the top side of the frame c Feed the power supply cable through the frame allowing 6 152mm of lead to remain inside the frame d Secure the power supply cable to the back box using cable clamps connector or other suitable strain relief allowing 6 152mm of lead to remain inside the inner housing e Ground ...

Page 4: ...y a qualified repair person MAInTenAnCe InSTruCTIonS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below user Cleaning Instructions 1 After the heater has cooled a vacuum cleaner with brush attachment may be used to remove dust and lint from exterior surfaces of th...

Page 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEqUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Page 6: ...6 notes notas notes ...

Page 7: ...s o chispas No lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manual Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléc trico o daños personales 11 Este calefactor está destinado a aplicaciones de calefacción ambiental y no es para util...

Page 8: ... mismo desde el tablero principal de servicio 2 Todos los procedimientos de cableado y conexiones deben hac erse de conformidad con los códigos nacionales y locales que ten gan jurisdicción y el calefactor debe estar conectado a tierra 3 La alimentación eléctrica debe ingresar a la caja posterior a través de los prepunzonados Verifique también la marca ARRIBA TOP de la caja posterior para asegurar...

Page 9: ...úe con el paso c b Extraiga el prepunzonado de la cara superior del bastidor c Pase el cable de alimentación eléctrica a través del bastidor dejando 152 mm 6 de cable dentro del bastidor d Asegure el cable de alimentación eléctrica a la caja posterior use abrazaderas o conector para cables u otro alivio de tensiones adecuado dejando 152 mm 6 de cable dentro del alojamiento interior e Conecte a tie...

Page 10: ...i por alguna razón el control de seguridad contra sobretemperatura no funciona como está previsto Si se activa este fusible térmico el calefactor no volverá a funcionar y debe ser reparado por un técnico de servicio califi cado InSTruCCIoneS de MAnTenIMIenTo Es importante mantener limpio este calefactor Su calefactor le brindará muchos años de servicio y confort con sólo un mínimo de cuidado Para ...

Page 11: ...PRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR qUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES qUE SE PRODUzCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos est...

Page 12: ...12 notes notas notes ...

Page 13: ... des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est prévu pour des applications de ch...

Page 14: ...tre en conformité avec les normes nationales et locales applicables et le radia teur doit être relié à la terre 3 L alimentation secteur doit entrer dans le boîtier arrière au travers des pastilles à enfoncer Voir également le marquage de HAUT sur le boîtier arrière pour la bonne orientation 4 Vérifiez que la tension du secteur arrivant au radiateur correspond bien aux valeurs spécifiées sur sa pl...

Page 15: ... alimentation secteur au travers de ce trou Puis enfoncez la pastille en haut du boîtier et passez à l étape C b Enfoncez la pastille sur le côté du dessus de l en cadrement c Passez le câble d alimentation secteur au travers de l en cadrement en laissant 6 152 mm de fils à l intérieur du boîtier arrière d Fixez ce câble sur le boîtier arrière en utilisant passe fils connecteur ou autre attache co...

Page 16: ...onS d enTreTIen Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ci dessous Instructions de nettoyage par l utilisateur 1 Une fois que le radiateur est froid vous pouvez utiliser un aspirateur avec son accessoire brosse pour él...

Page 17: ...eux doit être retourné au centre de réparation agréé par Marley le plus près ou au centre de réparation de la société Marley Engineered Products Il sera ensuite gratuitement réparé ou remplacé à notre discrétion et les frais de port de retour seront pris en charge par Marley Il est entendu que cette réparation ou ce remplacement constitue le seul et unique recours disponible auprès de la société M...