Alarms and faults
A46980-AB.doc
155/176
While the printer is operating
Malfunction
Actions and remedies
1-
Low ink level. Prep. cartridge:
50
1a-
Prepare a new ink cartridge.
2-
Low make
-
up level. Prep.
cartridge: 51
2a-
Prepare a new make
-
up cartridge.
3-
Empty ink level: 52
or
Drain cartridge absent.
3a-
Replace the ink cartridge.
4-
Empty make
-
up level: 53
4a-
Replace the make
-
up cartridge.
5-
Full cartridge draining: 54
5a-
In the draining or cleaning phase, insert a new
depressurized cartridge.
6-
Head temperature out of
range: 90
6a-
The ambient temperature of the location where
the printer is installed is too high, which leads to the
temperature inside the printer rising to above
70°C.(158º F) Change or cool the installation location.
6b-
Contact Markem
-
Imaje Technical Assistance.
7-
Console internal T° > 60°C
-
140°F
: 91
7a-
The internal temperature of the console is too
high. Ventilate the printer.
7b-
Contact Markem
-
Imaje Technical Assistance.
8-
Head cover absent: 84
8a-
Check the head cover and make sure it is closed.
8b-
Check the presence of the magnet in the cover.
8c-
Contact Markem
-
Imaje Technical Assistance.
Summary of Contents for 9028
Page 7: ...Contents A46980 AB doc 6 176 ...
Page 8: ...A46980 AB doc 7 176 Général ...
Page 10: ...A46980 AB doc 9 176 Presentation of the printer ...
Page 16: ...A46980 AB doc 15 176 Presentation of the operator interface ...
Page 32: ...A46980 AB doc 31 176 Using the printer ...
Page 53: ...Using the printer A46980 AB doc 52 176 ...
Page 54: ...A46980 AB doc 53 176 Editing a message ...
Page 114: ...A46980 AB doc 113 176 Servicing ...
Page 118: ...Servicing A46980 AB doc 117 176 Protect the head 1 2 3 4 ...
Page 121: ...Servicing A46980 AB doc 120 176 ...
Page 122: ...A46980 AB doc 121 176 Maintenance ...
Page 138: ...Maintenance A46980 AB doc 137 176 Replacing the air outlet filter Procedure 1 2 3 4 ...
Page 142: ...Maintenance A46980 AB doc 141 176 5 Remove the ink cartridge 8 6 9 7 10 ...
Page 144: ...Maintenance A46980 AB doc 143 176 Inserting the new module M6 1 4 2 5 3 6 ...
Page 145: ...Maintenance A46980 AB doc 144 176 7 8 9 ...
Page 147: ...Maintenance A46980 AB doc 146 176 ...
Page 148: ...A46980 AB doc 147 176 Alarms and faults ...
Page 160: ...A46980 AB doc 159 176 Technical Specifications ...
Page 168: ...Technical Specifications A46980 AB doc 167 176 Overall dimensions Console ...
Page 169: ...Technical Specifications A46980 AB doc 168 176 Head ...
Page 170: ...A46980 AB doc 169 176 External connections ...
Page 173: ...External connections A46980 AB doc 172 176 Alarm warning light RS232 link Tachometer encoder ...
Page 175: ...External connections A46980 AB doc 174 176 ...
Page 177: ...A46980 AB doc 176 176 ...