17
EN
EN:
IMPORTANT!
The drawings with the elements of automatics contain only visualisations of sample products.
IMPORTANT!
One wall-mounted HMI-EC controller can support the maximum of 8 curtain with EC motors.
The maximum length of the conductor, from the curtain to the programming device, is 100 m.
*The device does not contain:
main switch, fuses and feeder cable
Prior to the dismounting of any cover, shut down the electric power (at least by disconnecting the main switch). Electrical connection of the thermostat, door switch, valve actuator
or control panel is to be carried out before the device is connected to the electric power supply. Any potential changes to the electrical connections between control equipment and
control system of the device are to be carried out in the power off mode (disconnect at least the main switch). All electrical connection should be carried out by a qualified person,
according to the documentation delivered with the device, as well as the afore-mentioned connection diagrams.
Easyair W 100 EC
Easyair W
150 EC
Easyair W
200 EC
1.
28.5%
27.5%
28.0%
2.
B
3.
Total
4.
21
21
21
5.
VSD-No
6.
2020
7.
Mark Climate Technology, 02324861, Veendam (NL)
8.
1-2-2801-0232
1-2-2801-0233
1-2-2801-0234
9.
0.36kW, 2826m³/h, 145Pa
0.43kW, 4239m³/h, 124Pa
0.61kW, 6006m³/h, 128Pa
10.
1376RPM
1370RPM
1372RPM
11.
1.0
12.
Device disassembly should be performed and/or supervised by perperly qualified personnel having sufficient knowledge.
Contact a certified waste disposal company in your region. Explain what is to take place in terms of device disassembly
and subassembly securing. Disassemble the device using general procedures applied in mechanical engineering.
WARNING
The fan unit consists of heavy elements. These elements can fall down during disassembly, causing the death, severe
injury of the staff, as well as material damages.
Learn the following safety principles:
1. Disconnect the power, including all related subsystems.
2. Prevent the device from restarting.
3. Make sure the device is disconnected from power supply.
4. Secure or isolate all elements which are powered and situated nearby. To restore power supply, reverse the procedure.
Components:
In its dominant part, the device consists of of components made of steel, copper, aluminum and plastics, in varying
proportions (the rotor is made of SAN - styrene, acrylonitrile, structural material with the addition of 20% of glass fiber)
and rubber (neoprene) sockets/bearing hubs. The components must be sorted before recycling according to the following
material categories: iron and steel, aluminum, copper, non-ferrous metals, e.g. winding (winding insulation will be burnt in
the course of copper recycling, insulation materials, electrical wires, electronic waste (condenser, etc.),
plastic elements (fan rotor, winding shields, etc.), rubber elements (neoprene). The same applies to textiles and cleaning
substances used to disassemble the components. Elements should be separated according to local regulations or by a
specialist recycling company.
13.
Long period of defect-free operation depends on maintaining the product / device / fan in the scope of working parameters
specified by the slection and usage software, according to the intended purposes specified in the operation and
maintenance documentation enclosed to the device. To ensure correct operation of the device, always adhere to the
technical documentation, and particularly chapters: assembly, startup, use and maintenance.
14.
Fan housing, internal profiles
*1) general efficiency (η)
2) measurement category used to determine the energy efficiency
3) efficiency category
4) efficiency coefficient in the point of optimal energy efficiency
5) whether rotational speed regulation was taken into account in the calculation of fan efficiency
6) year of manufacture
7) manufacturer’s name or trademark, business register number and place of manufacture
8) product model number
9) rated motor power consumption (kW), flow volume and pressure in the point of energy efficiency
10) rotations per minute in the point of energy efficiency
11) characteristic coefficient
12) essential information to facilitate disassembly, recycling or dispose of the product after the end of its use
13) essential information to minimize the effect on the environment and to guarantee optimum use period, referring to disassembly, use and technical service of the fan
14) description of additional elements used in determining the energy efficiency of the fan
Summary of Contents for EASYAIR 100
Page 1: ...MARK EASYAIR 202106 62 610_R01 NL Technical manual Technisches Handbuch Technisch boek EN DE...
Page 2: ......
Page 18: ...18...
Page 34: ...34...
Page 57: ...57 EN NL...