The shower has a separate lensing pump to drain the water.
Read the user manual for the hot water tank and the
pressure water pump.
Read the user manual for the shower draining pump.
0.1.9 Common errors
Errors that may prevent free flow of water.
Blocked air ventilation of the water tank.
Blocked / full freshwater filter.
Automatic fuse for the freshwater pump has been released. For resetting
the fuse see the fuse panel placed starboard at the pilot position. (25 amp)
Marked
“Water pump”
The red light is not lighting if the fuse is working
correctly.
Micro-switch at the bottom of the pump is not working correctly.
Leakage in the system. Check all hoses and fittings.
The shower on aft bathing platform is not closed.
Section 4.08
0.29 Septic system/ Black water system
The system consists of the toilet (the head) and the septic tank. The system
works by discharging the black water through a bottom valve or by suction hose
emptying the tank by a stationary vacuum machine through a filler-fitting at the
side-deck on port side.
Shower drain pump
Shower and boiler drain
automatic sensor
Toilet flush button
Switch for toilet ventilation
230V outlet